Troubleshooting Procedures
2-16
[CONFIDENTIAL] Qosmio F60 Series Maintenance Manual (960-796)
Check 1
Convert the DC IN icon blink pattern into the hexadecimal error code and compare
it to the tables below. Then go to Check 2.
Table 2-3 Error code
Error code
Where error occurs
1*h
DC Power (AC Adapter)
2*h Main
battery
3:h 2nd
battery
4*h
S3V output
5*h E5V
output
6*h
E3V output
7*h 1R5-B1
output
8*h
1R05-P1V output
9*h PPV
output
A*h
1R5-PGV output
(
10G
)
1R05-P1V output
(
10
)
B*h PTV
output
C*h
PGV output
(
10G
)
IGD-PGV output
(
10
)
D*h SURS-PP
output
E*h
1R5-PGV output
(
10G
)
1R05-P1V output
(
10
)
F*h -
DC power supply (AC adapter)
Error code Meaning
10h
AC Adapter output voltage is over 20.92V.
11h
Common Dock output voltage is over 20.92V..
12h
Current from the DC power supply is over 8.00A.
13h
Current from the DC power supply is over 0.5A when there is no load.
14h
The compensation value of [0A] is not within the limits from design data (±
481mA).
Summary of Contents for Qosmio F60 Series
Page 11: ...1 Hardware Overview 1 2 Qosmio F60 Series Maintenance Manual 960 796 CONFIDENTIAL ...
Page 43: ...Troubleshooting Procedures 2 2 CONFIDENTIAL Qosmio F60 Series Maintenance Manual 960 796 ...
Page 119: ...Tests and Diagnostics 3 2 CONFIDENTIAL Qosmio F60 Series Maintenance Manual 960 796 3 ...
Page 293: ... CONFIDENTIAL Chapter 4 Replacement Procedures ...
Page 398: ... CONFIDENTIAL Appendices ...
Page 399: ...Appendices App ii CONFIDENTIAL Qosmio F60 Series Maintenance Manual 960 796 ...
Page 459: ...Appendix E Key Layout TECRA 9100 Maintenance Manual 960 347 3 ...