e-STUDIO281c/351c/451c
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
FUSER UNIT / PAPER EXIT SECTION
16 - 22
[D] IH coil (IH-COIL)
(1) Take off the fuser unit.
(
P.16-19 "[A] Fuser unit")
(2) Release the harnesses from 8 harness
clamps.
Fig. 16-19
(3) Remove 1 E-ring, 1 bushing and 2 screws.
Fig. 16-20
(4) Pull out the bracket and IH coil.
(5) Take out the IH coil from the bracket.
Notes:
1. When installing, be sure to set the har-
nesses “C” and “S” of 4 harnesses on
upper.
2. Make sure that there is not any scratch or
break on the white tube on the IH coil.
3. Make sure that there is not any peeling or
scratch on the harness tube.
Fig. 16-21
E-ring
Bushing
C
S
IH coil
Bracket