FUSER UNIT / PAPER EXIT SECTION
16 - 20
(3) Remove 2 screws and take off the cleaning
unit by lifting it up.
Note:
When installing, fit 2 protrusions on the bot-
tom of the cleaning unit into the holes of the
frame securely.
Fig. 16-13
(4) Remove spring (A) on each end of the oil
roller.
(5) Take off the oil roller.
Fig. 16-14
(6) Remove 1 bushing from each side of the oil
roller.
Fig. 16-15
Cleaning unit
Oil roller
Spring(A)
Oil roller
Bushing
Bushing