e-STUDIO281c/351c/451c
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
SCANNER
6 - 22
[F] Scan motor (M1)
(1) Take off the upper rear cover (
P.2-32 "[T]
Upper rear cover").
(2) Take off the rear cover-1(
P.2-31 "[R] Rear
cover-1").
(3) Disconnect 1 connector.
Fig. 6-31
(4) Release the harness from the harness
clamp.
(5) Remove 3 screws and take off the scan
motor with the whole bracket.
Fig. 6-32
Notes:
When installing the scan motor, use the belt
tension jig (spring). The procedure is as fol-
lows.
1. Fix the screw A.
(
P.6-22 "Fig. 6-32 ")
2. Temporarily fix the screw B and C.
(
P.6-22 "Fig. 6-32 ")
3. Hook the belt tension jig to the motor
bracket and the flame.
4. The scan motor is pulled by the belt ten-
sion jig. Fix the screw B and then C at the
stopped position.
5. Remove the belt tension jig.
Fig. 6-33
C
Scan motor
A
B
Belt tension jig