1600/2000/2500 COPYING PROCESS
3 - 18
December 2000 © TOSHIBA TEC
Fig. 3-4-27
11. Detach the bushing located in rear side.
12. Slide the bushing located in the front.
Fig. 3-4-28
13. Detach the magnetic roller assembly.
Fig. 3-4-29
14. Detach the bushing.
15. Detach 2 washers and the 2 magnetic roller
spacer.
Fig. 3-4-30
01/11
Reference
position
Doctor blade
Doctor blade seal
Doctor blade
3-4-27
Bushing
Bushing
3-4-28
1
2
3-4-29
Magnetic roller
Bushing
Washer
Magnetic roller
spacer
Magnetic roller
Washer
Magnetic roller
spacer
3-4-30
2. Attach the doctor blade seal to the doc-
tor blade at the position described in right.