1600/2000/2500 SCANNER
7 - 20
December 2000 © TOSHIBA TEC
4. Remove the double-sided tape and remove the
ADF glass.
Note:
For installing the ADF glass and original
glass and adjusting the tilt, refer to the Ser-
vice Handbook. (See Chapter 1.8)
Fig. 7-8-7
ADF glass
Original glass
043-2
[B] Original glass
1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, open it.
2. Remove 2 screws and remove original glass
stay.
3. Remove 4 screws and remove original glass.
Fig. 7-8-6
Screw
Screw
Original glass stay
Original glass
043-1
25. Release the clamp and take out scanner as-
sembly.
Important:
1. After the replacement of the scan-
ner assembly, download firmware
for the scanner PWA. For details,
see chapter 5 of the Service Hand-
book.
2. Download the MAIN PWA firmware,
if necessary, after confirming the
version of it.
3. When the error message “F14” ap-
pears after replacing the scanner
assembly, refer to the Service
Handbook and perform (08-389).
Note:
When mounting scanner assembly, be care-
ful not to damage the actuator.
Scanner assembly
Clamp
Fig. 7-8-5
042
Summary of Contents for DP1600
Page 1: ...DIGITALPLAINPAPERCOPIER DP1600 2000 2500 File No 31100011 R0111216600 TTEC ...
Page 2: ...Copyright 2000 TOSHIBA TEC CORPORATION ...
Page 232: ...1600 2000 2500 PCB BOARD 16 2 December 2000 TOSHIBA TEC 16 2 PWA F RLY 16 02 01 ...
Page 233: ...December 2000 TOSHIBA TEC 16 3 1600 2000 2500 PC BOARD 16 3 PWA F PIF 16 03 01 ...
Page 237: ...17 WIRE HARNESS CONNECTION DIAGRAMS 17 1 ...
Page 264: ...1 1 KANDA NISHIKI CHO CHIYODA KU TOKYO 101 8842 JAPAN ...