4.5 Printer Parameter Fine Adjustment
4- 47
4.5.6 Transmissive Sensor Manual Threshold Fine Adjustment (THRESHOLD<T>)
This parameter is to set a threshold voltage of the feed gap sensor.
Notes:
1. When
the
[FEED]
key is pressed, the menu moves in the opposite direction from when the
[PAUSE]
key is pressed.
2. When
the
[PAUSE]
key is pressed while the
[FEED]
key is held down, or when the
[POWER]
key is
pressed for 3 seconds or more, the display returns to the system mode menu (ADJUST SET).
3. When
the
[FEED]
key or
[PAUSE]
key is pressed for 0.5 seconds or more during this fine adjustment
setting, repeat mode is enabled and the key pressed is repeatedly entered.
4. The change in the fine adjustment value becomes effective when the
[POWER]
key is pressed after
setting, then stored in the backup memory.
5. The factory default value is 1.4V.
6. This setting is effective only in the TPCL and TPCL1 modes.
[PAUSE]
THRESHOLD<T>0.0V
THRESHOLD<T>0.1V
THRESHOLD<T>0.2V
THRESHOLD<T>3.9V
THRESHOLD<T>4.0V
[FEED]