TOSHIBA
4 - 6
Terminal Block
ST
FM
AM
CC
CC
RX
PP
IV
FP
FLC
FLB FLA
P24
RES RR
F
R
S1
S2
S3
S4
RCH
A
RCH
C
LOW
A
LOW
C
To run from a pot, the H3 must have:
1) Drive enable ("ST"-"CC" made)
2) Direction command ("F" or "R" to "CC" made)
3) Frequency reference ( wiper from pot is read via "RR" terminal )
4) LOCAL/REMOTE LED off (puts drive in remote mode).
Toggle the LOCAL/REMOTE button on keypad to turn LED off (with drive stopped).
Notes:
1) Use a 3K ohm pot (1 to 10 K ohms will work).
2) The drive will accel to commanded frequency when "F" or "R" to "CC" is made.
3) The drive will decel to 0.0 Hz when "F" or "R" to "CC" is broken.
4) Motor will coast to a stop if "ST" to "CC" is broken.
5) The above information applies to a H3 with factory default programming.
stop/start
Wiper
(usually middle terminal)
Connection Examples: Potentiometer Operation