Mar. 2000 © TOSHIBA TEC
13 - 9
8070/6570/5570/4580 CLEANER UNIT
[C] Recovery blade
(1) Remove the recovery blade.
Notes: 1. The recovery blade is secured by dou-
ble-sided adhesive tape. Make sure that
the tape is completely removed before
securing the new blade.
2. When installing the recovery blade, press
the edge of the recovery blade against
the stepped section of the cleaner frame,
and fix at point
A
making sure that there
is no gap.
[D] Fur brush
(1) Draw out the support shaft knob of the fur brush
in the direction of the arrow to set the fur brush
to a free state.
(2) Remove the fur brush from the cleaner body.
Recovery blade
Fur brush
A
Recovery
blade
Drum surface
Cleaner casing
[E]
Toner adhesion amount sensor
(1) Remove the sensor mounting bracket (2
screws).
Summary of Contents for 4580
Page 1: ...SERVICE MANUAL DIGITAL PLAIN PAPER COPIER 8070 6570 5570 4580 ...
Page 231: ...6570 5570 DEVELOPER UNIT 12 28 Mar 1999 TOSHIBA TEC 3 Draw out the toner filter ...
Page 252: ...8070 6570 5570 4580 FUSER UNIT 14 6A Mar 1999 TOSHIBA TEC ...
Page 369: ...8070 6570 5570 4580 ADF 16 78 Mar 2000 TOSHIBA TEC 16 13 PC Board 1 PWA F LGC 794 ...
Page 370: ...Mar 2000 TOSHIBA TEC 16 79 8070 6570 5570 4580 ADF 2 PWA F SEN 794 ...
Page 374: ...Mar 1999 TOSHIBA TEC 18 1 6570 5570 PC BOARD 18 PC BOARD 1 PWA F SYS 300 ...
Page 375: ...6570 5570 PC BOARD 18 2 Mar 1999 TOSHIBA TEC 2 PWA F MTB 300 ...
Page 376: ...Mar 1999 TOSHIBA TEC 18 3 6570 5570 PC BOARD 3 PWA F LGC 300 ...
Page 377: ...6570 5570 PC BOARD 18 4 Mar 1999 TOSHIBA TEC 5 PWA F MOT 300 4 PWA F ADU 300 ...
Page 378: ...Mar 1999 TOSHIBA TEC 18 5 6570 5570 PC BOARD 6 PWA F SLG 300 7 PWA F SDV 300 ...
Page 379: ...6570 5570 PC BOARD 18 6 Mar 1999 TOSHIBA TEC 8 PWA F PLG 300 ...