Apply the steady force Q (ca 500 N) on the work spindle end in down vertical direction. The measuring of the change in
position of work spindle end should be taken by dial indicator in the force F acting direction and its gradual enlarging (force
F must be the same but opposite to the force Q - see fig. 5.5-a.
From the course of gradual changes of work spindle position and force F construct the diagram of bearing load analogous to
the diagram in fig. 5.5-b which the clearance ratio in measured bearing is to be read from - (values Z1 (Z2)).
Taking up the clearance (or prestress) should be done by shifting of the inner ball race of a value a1 and (a2) which can be
evaluated or read from the table in fig. 5.5.
Calculation of values a1 and (a2):
The front bearing (the mean interference value recommended 0,003)
a1=14 . (
M
M
N
+
1
. Z1+0,003)
The rear bearing (the mean clearance value recommended 0,001)
Summary of Contents for SUA 125 NUMERIC
Page 39: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 39...
Page 41: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 41...
Page 43: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 43 5 2 3 Brake Fig 5 2 Fig 5 2 6...
Page 46: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 46...
Page 48: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 48 5 2 6 Work spindle Fig 5 4...
Page 57: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 57...
Page 63: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 63 Hydraulic chart...
Page 64: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 64...
Page 68: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 68 Fig 5 8...
Page 70: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 70...
Page 75: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 75...
Page 93: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 93 Fig A transport locking...
Page 95: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 95...
Page 109: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 109 Fig B Working path length is 650 mm...
Page 110: ...SUA 125 NUMERIC 34200003 TOS a s 02 2011 110 Longitudinal stops Fig C...