Error messages
EN
DE
Display
Cause
Troubleshooting
E33
General communication error
Check the plug connections on the cables.
Check the cables.
Switch the motor off and on again.
E34
Emergency Stop on
Reset the Emergency Stop button to the 0 position.
E43
Battery flat
Charge the battery.
It may be possible to restart the motor slowly from the Stop position.
Other error codes
Defect
Contact Torqeedo Service and provide error code. Check power source,
main fuse, and main switch.
If power supply is working correctly: Contact Torqeedo Service.
Nothing is shown on display
Defective, or no voltage
Check power source, main fuse, and main switch. If power supply is
working correctly: Contact Torqeedo Service.
Battery (applies only when operated with Power 48-5000 battery)
Display
Cause
Troubleshooting
E70
Over/undertemperature while charging
Correct the cause of deviation from temperature range; if necessary,
remove charger unit and allow it to cool down.
Switch battery on and off.
E71
Over/undertemperature while discharging
Correct the cause of deviation from temperature range; if necessary,
temporarily stop using the battery, so that it can cool down.
Switch battery on and off.
E72
Excess temperature of battery FET
Allow battery to cool down.
Switch battery on and off.
E73
Overcurrent when discharging
Correct the cause of the overcurrent.
Switch battery on and off.
E74
Overcurrent when charging
Remove charger unit. (Use only Torqeedo charger unit)
Switch battery on and off.
page 95 / 116