36
1.
Setting the Reference ET Value
Turn the
Upper Line
knob to view the following display:
By setting a
Reference ET
value based on the highest ET demand
period of the year, proper watering is ensured for the entire year.
REF. ET PART 1 STA 01
1.00 (Weekly ET 1.00)
5.
Turn the
Upper Line
knob to view the following display:
REFERENCE MONTH STA 01
JUL (7 days/week)
6.
Turn the
Lower Line
knob to change the month.
7.
Turn the
Upper Line
knob to view the following display:
PROGRAM COMPLETE STA 01
This completes the program setup process for a User-With ET
schedule format. To program additional stations, return to the
beginnning of Chapter 4 on page 21.
STOP:
Note:
If the selected station number uses the
Set Days
water
day schedule,
Reference Month
menu item will be accessable.
To adjust this setting, continue at step 5.
If the
Set Days
schedule is not used, continue at step 7.
1.
2.
The whole number of the
Reference ET
value is selected by default.
To adjust the value from
1 – 3
, turn the
Lower Line
knob.
4.
Turn the
Lower Line
knob to adjust the decimal number value.
3.
Turn the
Upper Line
knob right one stop to select the decimal
number.
Note:
The
Reference ET
value is adjustable from
0.50 – 3.99
. The
whole number is only adjustable to
0
when the decimal number
value is
.50
or higher.