©Tornado International Ltd. 2019
-9-
Confidential
1.05 Chargers
Air vents
Air vents
Charge indicators
Batteries
The chargers must be mounted on a wall using the slots in the rear of the case (see Dia 2). Draw a 325mm
horizontal line on the wall on which you want to mount the charger case and drill a hole at each end. Use
the rawl plugs and screws provided in the spares pack (1F00-001 - Charger & PSU fixings) to create the
mounts.
Air vents at the top of the case and above the battery enclosure provide cooling. It is important that the
chargers are positioned so that there is an uninterrupted flow of cool air over the vents.
Caution!
The chargers must be mounted indoors and in such a position that the public do not have access to them.
They must be protected from water.
The chargers should now be connected to the electric supply. The batteries are fully charged when the
unit is dispatched from the factory, however if the unit has been in transit for some time it might be
prudent to charge the batteries whilst the rest of the installation is carried out. See the section “3.19
Battery charger” for how to charge the batteries.
Mains input
Dia 1 - The charger case
Mounting slots
Dia 2 - Case mounting slots
1N00-510 Genesis Boat User Manual v3 05/19