PROGRAMMING PARAMETERS ON THE T120-T240
ENTER
DOWN
Code
Description
Parameters set from digital switch
Not used
Emergency battery ( without dot=battery present ; with dot=battery not present)
Partial opening (without dot=disabled =70%, with dot=enabled =40%)
Seal on closure ( without dot=disabled=0; with dot=enabled=Level 2 )
Automatic and partial reclosing time ( without dot=disabled=5 ; with dot=enabled=0 )
Opening speed adjustment at 45cm/s and closure at 25cm/s
Opening/closing speed increase at 45cm/s
Opening speed increase at 65cm/s and closure at 35cm/s
It is possible to enter the basic parameters using the 7 segment display
(Fig.37)
and the
<ENTER> and <DOWN> keys.
Press and hold <ENTER> for 5 sec to enter the configuration menu.
Press <DOWN> to pass from a parameter to another, press <ENTER> to enable/disable
the function.
The presence on the display of a dot next to a parameter code indicates that the function is
enabled.
WITHOUT DOT-monitored sensors (with test) type Optex OA-Axist T or
Hotron HR100_CT
WITH DOT-NC not monitored sensors (without test connection)
Safety logic:
Press and hold 'DOWN' for 5 sec. to enter radio programming and enable remote controls.
By keeping hold the “DOWN” key for another 15 seconds, all remote controls connected to the electronic board will be deactivated.
To program the radio control devices (up to 8):
press the “DOWN” key and hold for 10 seconds.
The sequence of characters “Radio” appears; at this point:
- If you have the remote control kit Topp TS2 press the smooth side of the first key (function open) until, one letter at a time,
the word RADIO flash on the 7-segment display.
- If the Topp
TS1
4-channel remote control kit is available, press the second key (Close Function).
ATTENTION:
The automation software is designed to perform automatic recovery in the instance where anomalous events as
described in
chapters 5.8-5.11.
The automation in order to perform the above, if set in a mode other than "Closed", perform a reset called "Near" that
provides for the complete opening and closing of the doors at a low speed, before returning in the set state the function
selector.
The recovery action must be taken into account in applications where there are features that provide access
control with inputs different from those of the radar for which automation could not ensure the operating mode
set.
In case you want to exclude the auto recovery please contact support Topp Srl.