29
SERVOASSISTED FUNCTION WITH DISABLE USER BUTTON
By connecting the external and internal opening buttons as per the following diagram and correctly setting parameter
113 on the board, the door will enter Servo / Push & GO mode. Setting parameter 113 = 3, the Push & GO function is
activated with safety sensors activated Setting parameter 113 = 2 the Push & GO function is activated with sensors
deactivated it is necessary to activate the LOW ENERGY.
DISABLED USER RESTROOM DOOR FUNCTION (parameter 135 =9)
The system functions sequentially:
•
When the restroom is free, pressing the ex
-
ternal button opens the door.
• If the door is closed pressing the internal
button closes the door and locks it with the
electric lock, signaling that the restroom is
occupied.
• Pressing the internal button opens the door if
the door is not closed.
•
The door is equipped with an electric lock
connected to the input board.(see pag.16)
The external radar input (22 ) should be con
-
nected to a button on the outside of the re-
stroom.
•
The internal radar board input (18 ) will be
connected to a button on the inside of the re-
stroom.
•
On the output of the air curtain (6 ) a flush
command can be installed.
• The output on the disabled user restroom
display (5) is connected to a display that
shows “occupied” or “free”.
•
Set a time parmeter 122 sufficiently long to
allow a disabled user to enter the restroom.
•
Set the parmeter 104 = 0
DISABLE SPECIAL FUNCTIONS
instructions for installation
S200
1 9 17 2
5
6 14 22 3
0
2 10 18 26
3 11
19 2
7
8 16 24 3
2
7 15 23 31
4 12 20 2
8
5 13 21 2
9
occupato
5
6
18
22
E
I
8
20
Summary of Contents for S200
Page 20: ...20 instructions for installation LIST OF ERROR MESSAGES AND NOTICES S200 ...
Page 26: ...26 instructions for installation PRE WIRED ELECTRIC CONNECTIONS S200 ...
Page 30: ...30 EC DECLARATION OF CONFORMITY instructions for installation S200 ...