19
instructions for installation
MAINTENANCE - PARTS REQUEST - DEMOLITION - NEAR
S200
MAINTENANCE
A regular maintenance is required to ensure the correct operation of the automation, this maintenance activity may be
carried out either by TOPP, in accordance with a specific agreement made with the user, or by the installation technician
or by other competent and qual-ified technical personnel in possession of all legal requirements.
All works of maintenance, except functional alterations, must be carried out with the door closed and the power discon
-
nected (including the emergency battery).
The recommended periodical routine maintenance should include at least the following activi-ties:
Every 3 months:
If present, check the battery charge level:
1) Turn on automation
2) Enter programming mode and configure parameter 110: with a value other than “0”
3) Exit programming and disconnect the 230V power supply to the automation.
In the event that the leaves do not open, the emergency batteries must be replaced.
Every six months:
• Check the door glide and eliminate any friction; make sure the hinges are in good condition and not worn;
• clean the radar and safety sensors with non-abrasive detergents;
• check that there are no blind spots in the vicinity of the moving doors which might not be detected by the radar and
safety sensors;
•
check the stability of the automation and secure fastening of all the screws: actuator - arm;
• check the connections and electric wiring;
•
power the automation and check the stability of the door, making sure that the movement of the panels is smooth
and friction-free; disconnect the power and check that the emergency batteries open the door completely on the
passageway;
•
if worn, change the arm and other worn parts.
Every 24 months:
•
replace the emergency battery system (remember to disconnect the power).
•
The duration of the battery back is affected by the environmental and functional conditions of the automation.
ACCESSORIES AND PARTS ON REQUEST
Always use original spare parts and accessories. Non-original parts could endanger safe and efficient operation of the
automation. Original spare parts and accessories must be ordered exclusively from the dealer or manufacturer, commu
-
nicating the type, model, serial number and year of construction of the automation.
DEMOLITION
Demolition of the automation must be carried out in respect of the legislation in force on the subject of environmental
safeguards. The mandatory first step is to proceed with differentiation of the parts of the automation according to the dif
-
ferent types of material.
The emergency battery must be removed from the device before disposal (remember to disconnect power) because the
battery pack contains hazardous substances that must be eliminated safely.
“NEAR” Function
It performs a re-alignment of the operator in case of upcoming errors
To activate the procedure press and hold for 2 seconds the “NEAR” button on the analog selector,
To activate the procedure use the dedicsted command on the DS2S digital selector,
To activate the procedure press and hold for 2 seconds the “CLOSE” buttin of the TS1S wireless function selector
OPERATOR RESTART IN CASE OF POWER CUT (NEAR)
Whenever the operator is switched off (voluntarily or after a power cut), once it is restarted, a soft reset “NEAR” procedure
is automatically performed by following the setting of the parameter 117 (default value “0” ) the automation self-realigns
with the door in closed position.
If the automation was pre-set in CLOSE mode, the NEAR (re-alignment) will be performed only at the first operation
(through impulse) or once the door mode will be changed from CLOSE. The re-alignment will follow the setting of pa
-
rameter 117.
SAFETY CONCERNS: BRAKING
The system is equipped with a braking circuit that acts in case of
grave error on the board,
absence of power and
battery is low.
The buzzer sounds when there is an error in the system.