DIGITAL PROGRAM SWITCH
The switch with digital keys. model DS2, for surface installation, serves to select different operating modes of the door using
the keys. The program function selected is signaled on the luminous display.
LIST OF MODES
100
14.5
77.5
This will allow you to scroll the menu upward
This allows you to increase the value of the function selected
This allows you to confirm the function selected and change mode.
In case of error, if you press this key for 3sec, it will reset to zero
(near).
This allows you to decrease the value of the function selected and
return to the previous menu
This allows you to scroll the menu downward. Hold for 4 sec to
enter the menu
TOTAL ENTRY/EXIT
- The external/internal sensors are enabled, the door block is off and the
automatic opening of the door is total.
PARTIAL ENTRY/EXIT
- The external/internal sensors are enabled, the door block is off and the
automatic opening of the door is reduced.
OPEN
- The door opens automatically from whatever position it is in, and remains blocked with the
door open.
PHARMACY -
The door has a reduced opening for safe exchange of goods, all sensors are
disabled. Requires an additional electric lost. Opening is activated via remote control or key
impulse.
CLOSED
- The door closes automatically from whatever position it is in, all the sensors are
disabled and the door block is on.
ENTER ONLY
- The internal exit sensor is disabled, the external entry sensor is enabled and the
door block is on.
EXIT ONLY
- The external entry sensor is disabled, the internal exit sensor is enabled and the door
block is on.
Door 1 open -> door 2 does not open as long as the door 1 is open
INTERBLOCK
- You enable the interlock function of a pair of doors (eg. 1/2 and 3/4). The interlock
provides the combined operation of two doors operated by a single switch that can DS2
essereimpostate in: single output, single entry and automatic. Here's an example:
Door 2 opening -> door 1 does not open as long as the door 2 is open.
To enable interlock enter the menu PARAMETERS -> INTERLOCK -> YES.
WINGS FREE -
– The door stops, all sensors and inputs are disabled. The panel locking system
disconnects (if any). Panels are free. The door can be opened or closed manually.
Summary of Contents for DUEVILLE
Page 2: ......
Page 52: ...52 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Page 53: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 53 ...
Page 54: ...54 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Page 55: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 55 ...
Page 56: ...56 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Page 57: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 57 ...
Page 58: ...58 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Page 59: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 59 ...