![TOPP DUEVILLE Instructions For Installation And Use Manual Download Page 20](http://html.mh-extra.com/html/topp/dueville/dueville_instructions-for-installation-and-use-manual_1129585020.webp)
4.1
GENERAL RECOMMENDATIONS
IT
ELECTRICAL CONNECTION
4
&
We recommend the following types of power cables: H05VV-F 3X0.75, H05RN-F 3X0.75.For the analogue switch cable
we recommend using a multipole 8 x 0.5 cable type LI-YY, and for the digital switch 4x0.5 LI-YY. (Cable ‘shielding’ should only
be used for cable lengths in excess of 20 meters).
&
Whatever type of electrical material is used for connection (plug, cord, terminals, etc.), it must be suitable for the use, with
the “CE” seal of approval and must comply with the requisites foreseen by the laws in force in the country of installation. For
the wiring, use cables with double insulation up to the immediate vicinity of the connectors.
Electrical connection of the automation must be made exclusively by qualified technical personnel in possession o fthe
professional requisites foreseen by the laws in the country of installation, who must issue the client a certificat eof
conformity of the connection and/or installation made.
&
The electrical power line to which the control unit is connected must comply with the requisites foreseen by the laws in force
in the country of installation, and must comply with the technical requisites listed in table 1 and on the “CE” rating plate .
&
The power supply system to which the equipment is connected shall be provided with an omnipolar magneto-thermal
differential 30mA switch with aperture of at least 3 mm between the contacts. This device shall be installed in the power supply
system in accordance with the requisites contemplated in the legislation in force in the country of installation.
&
Before making electrical connection of the automation, make sure the power cord has not been damaged.
&
The installation must include a ground wire longer than the power cord so that, in case of traction, the ground wire is the last
to stretch.
&
The hole drilled on the profile for passage of the power cord must be made without any rough or sharp edges or sharp
corners that could damage the wire.
Fig.
8
2. Input for program selector
input with knob
1. Infrared sensor input,
microwave sensors,
photocells, door opening
safety guard
4. Digital switch input
5. Input for air curtain, lamp,
key switch, emergency key,
smoke detectors
6. Emergency battery system
input
3. Input for lateral guards,
antipanic device and test
sensors
7. Gearmotor input
8. Door block 1 input
9. Door block 2 input
(pharmacy)
10. Transformer input
13. DOWN key
11. Lighted display
12. Encoder cord input
14. ENTER key
Ds2
Ds3
Ds4
10
9
8
5
3
1
2
4
12
PC
don’t touch
14
11
13
6
7
4.2
ELECTRONIC CIRCUIT BOARD
20
EN
INSTRUCTIONS FOR INSTALLATION AND USE
DUEVILLE
Summary of Contents for DUEVILLE
Page 2: ......
Page 52: ...52 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Page 53: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 53 ...
Page 54: ...54 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Page 55: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 55 ...
Page 56: ...56 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Page 57: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 57 ...
Page 58: ...58 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Page 59: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 59 ...