DUEVILLE
If the first resetting operation is positive, the automation will start working properly again though storing the error in the
error history file.
Should the first reset fail, the automation will make an attempt every 30 sec for max 24 hours. If the error is not solved
within 24 hours, the automation will eventually stop working and the intervention of a professional will become
necessary.
Should errors
F, G, h, I
or
J
occur, the automation will automatically perform the sensors resetting operation.
If the doors are smashed until the automation mode is closed and subsequently repositioned does not run no movement
reset.
For proper operation of the automated system with panic mounted photocells TOPP F3.
Following the collapsing of the leaves, only for model with pre-panic, automation stops waiting for the manual
repositioning of the doors themselves. Subsequent to closing the automation will remain stationary in the position taken
before the breakthrough for a time equal to 20 seconds, after which it will perform a reset (near).
The opening of emergency or fire causes the immediate opening of the automation, but in case where the sensors side are
occupied. As long as the contact remains active automation remains open, once the contact is deactivated automation will
return to the operation previously set by digital switch DS2 or analog selector Ms1.
The emergency opening or opening fire is manageable via a control unit or an emergency button connected to the card (
see
page 24
).The setting of the logic of contact on the card type is NO (normally open). The logic of contact it can be varied only by
the digital switch DS2 in the PARAMETERS MENÙ -> PAR. VARIOUS -> LOGIC EMER. for the logic of emergency contact
and PARAMETERS -> PAR. VARIOUS -> LOGIC ANTINC. for logic fire.
5.9
5.11
SELF RESTORE MANAGEMENT OF ERRORS F-G-h-I-J
SELF RESTORE MANAGEMENT AFTER OPENING FIRE OR AN OPENING OF EMERGENCY
5.10
SELF RESTORE MANAGEMENT AFTER ANTI PANIC ALARM
Once freed sensors the reset (near) resumes automatically. Throughout the zeroing phase (near) the automation will
move at a reduced speed.
If there is one of the errors mentioned above as long as it is set to the "CLOSED" by DS2 digital or analog selector switch
MS1, automation will not perform any reset (near) as long as this mode will not be changed, or if it will request the
opening of impulse key or emergency opening / fire. Once changed how automation will perform the reset (near) as
shown above.
Summary of Contents for DUEVILLE
Page 2: ......
Page 52: ...52 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Page 53: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 53 ...
Page 54: ...54 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Page 55: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 55 ...
Page 56: ...56 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Page 57: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 57 ...
Page 58: ...58 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Page 59: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 59 ...