INSTALLATION MANUAL
page 52 / 60
Programming of CLIP generation
If Caller ID is enabled, you can select the mode of sending out ID (by FSK or with DTMF) and its
timing – before the ringing signal or after it.
- for CLIP generated after the ringing signal, in mode ETSI FSK, you dial 510
- for CLIP generated before the ringing signal, in mode ETSI FSK, you dial 511
- for CLIP generated after the ringing signal, in mode ETSI DTMF, you dial 512
- for CLIP after the ringing signal, in mode ETSI DTMF you dial 513.
Programming of billing signal generation.
Teletax signal for billing can be generated, either over 12 or 16 KHz (out of band).
- no billing signal generated, you dial 520 (default setting).
- billing signal with 12kHz frequency is generated, you dial 521
- billing signal with 16kHz frequency is generated, you dial 522.
Programming of timer for billing signal, minute minder
- you dial “60xyz”, where xyz is the value in seconds of the timer, such as 20120 for 120
seconds. The minim value is 2 seconds and maximum is 600 seconds.
Programming of timer preminder
If enabled, “preminder minder” audio signal will be generated at a few seconds before the end of
each billing period.
- dial 61xyz, where “xyz” is the value in seconds of the preminder timer.
- the maximum value is the value of the minder minus one second
- example : if the time quanta for billing is of 60 de seconds and you want to sound a
warning 5 seconds before the billing period occurs, you should dial : 60060 and respectively
61055.
Programming of the timer for dialing
- you dial 62xyz, where “xyz” is the value in seconds of the timer, minimum two seconds,
maxim 600 seconds
Programming of hotline timer:
- you dial 81x, where x is the value in seconds to enable hotline service; minimum value is
one second, maximum is 5.
Programming of the number for hotline:
- you dial 82dig1dig2...dign#. So you must dial at first “82”, then the string of digits, and
you end with a “#”.
Programming of generation of minute minder signal
- no generation of minute minder, you dial 330
- to generate minute minder, you dial 331
Programming of timer for billing signal, minute minder
- you dial 6xyz, where xyz is the value in seconds of the timer, from a minimum of
2 seconds up to the maxim of 600 seconds.