22
NOTE:
You may need to increase the stall force in cold weather due to increased resistance from
gate hinges. The gate opener’s opening/closing force is adjusted automatically according to stall force
adjustment.
NOTE:
If the “11” is be set, the gate opener won’t work until the PBS system is equipped. The PBS
system works only when gate opener is closing. The gate opener will return to its open position when
the obstruction blocks the beam from photo eye.
6-a Adjust Stall Force of Actuator 1
Now we adjust the stall force of actuator 1
The stall force of actuator1 is adjusted by pressing “
INC
” and “
DEC
” buttons respectively. The Digital
Display will show “1”-“9” which indicates the stall force levels. “1” means the minimum force, and “9” is the
maximum force. Each time you press and release the “
INC
” button, the figure increase by 1, and the force
increases to a higher level. Each time you press and release the “
DEC
” button, the figure decreases by 1,
and the force decreases to a lower level. Press “
FUNC
” to store the data. The Digital Display will indicate
“P6”. Now stall force of actuator 1 is finished.
(Factory default setting is Level 4)
6-b Adjust Stall Force of Actuator 2
When the Digital Display indicates
“P6”
.you can adjust force of actuator 2.
Please perform the same procedure as gate opener 1 (6-a).
Press the “
FUNC
” button to store the data when stall force of actuator 2 is set. Then “P7” will be shown on
the Digital Display.
7. Set the Pressing Force to the gate block
When the Digital Display indicates
“P7”
, the gate opener is in the setting of the pressing force to the gate
block.
When the gate runs to the limit position, the gate block force it to stop. To reduce the damage to the gate
opener, the pressing force to the gate block is needed to adjust to a proper value. Press
“INC
” and “
DEC
”
buttons respectively to adjust the force. The Digital Display will show “1”-“3” which indicates the stall force
levels. “1” means the minimum force, and “3” is the maximum force. Press “
FUNC
” to store the data. The
Digital Display will indicate “P8”. Now setting of the Pressing Force is finished.
(Factory default setting is Level 2)
8. Set the Safety Photocell Beam System (PBS) (Optional)
When the Digital Display indicates
“P8”
, the gate opener enters PBS set mode.
You can press and release the “
INC
” or “
DEC
” button to set or shut off the PBS function. The Digital Display
indicates “11”, the PBS is available. The Digital Display indicates “00”, the PBS is null.
Press the “
FUNC
” button to store the data when the PBS is set. The Digital Display will indicate “P9”.
(Factory default setting is “00”)
9. Set the Automatic Closing Time
When the Digital Display indicates
“P9”
, the gate opener enters into the setting of automatic closing time
mode. Press and release the “
INC
” or “
DEC
” button, the Digital Display will show a “00”-“99” which
indicates the current automatic closing time. The minimum time is 0 second, 99 seconds maximum. Each
time you press and release the “
INC
” button, the figure increases by 1, and the timing increases by 1
second. Each time you press and release the “
DEC
” button, the figure decreases by 1, and the timing
decreases by 1 second. When the timing is “00”, the automatic closing function is shut off and the gate will
stay open.
(Factory default setting is 60 seconds)
Press the “
FUNC
” button to store the data when the desired automatic closing time is set. The Digital
Summary of Contents for CASAR HJ4021