23
NOTE:
If the master gate quick operating is enabled, the master gate won’t be operated quickly by
pressing button B of the remote control until both gates are fully closed. And the digital display will alarm
with “E4”.
Display will indicate
“PA”
10. Set the Period of Soft Stop
When the Digital Display indicates
“PA”
, the gate opener is ready for setting period of soft stop.
You can press the “
INC
” or “
DEC
” button to set the period of soft stop. There is 1-9 seconds available in
setting. Press the “
FUNC
” button to store the data when the period is set. The Digital Display will indicate
“Pb”
.
(Factory default setting is 2 seconds)
11. Enabled/Disabled the Master Gate Quick Operating
When the Digital Display indicates
“Pb”
, you can enable/disable the master gate quick operating.
You can press and release the “
INC
” or “
DEC
” button to enable or disable the master gate quick operating.
The Digital Display indicates “01”, the master gate quick operating is enabled. The Digital Display indicates
“00”, the master gate quick operating is disabled. When the master gate quick operating is enabled, you
can use the button B of the remote control to operate only the master gate without changing the dual/single
gate setting when both gates are fully closed. The master gate (Motor1 in dual gate mode) will run the time
of “
PC
” setting and then stop automatically.
Press the “
FUNC
” button to store the data when the master gate quick operating is set. The Digital Display
will indicate “
PC
”.
(Factory default setting is “00”)
.
12. Set the Running Time of the Master Gate if it’s Quick Operating Enabled
When the Digital Display indicates
“PC”
, the gate opener is ready for setting the running time of the master
gate if the quick operating is enabled.
Press and release the “
INC
” or “
DEC
” button, the Digital Display will show “00”or“01” which indicates the
current setting. “01” shown in Digital Display, the master gate will run 4 seconds and stop automatically
when master gate quick operating is activated. “00” shown in Digital Display, the master gate will open fully
when master gate quick operating is activated. You can press and release the “
INC
” or “
DEC
” button to
change the setting.
Press the “
FUNC
” button to store the data when the running time of the master gate is set. The Digital
Display will indicate “
Pd
”.
(Factory default setting is “00”)
13. Return to Factory Default Setting
When the Digital Display indicates
“Pd”
, press and release the “
INC
” or “
DEC
” button. All data will return to
factory set, the Digital Display indicates
“dF”.
Press “
FUNC”
Button to back to standby mode. The LED will
display
“--”
again when it enters the standby mode.
Digital Display When Gate Opener is Running
The right/left image on Digital Display separately symbolizes motor of actuator 1/actuator 2 when the gate
opener is running.
When actuator 1 is running, the right LED displays “n” (gate opening) or “u” (gate closing).
When actuator 2 is running, the left LED displays “n” (gate opening) or “u” (gate closing).
When the Gate Opener is not running, the Digital Display indicates “- -” (standby).
NOTE: Once the LED display an error code“E1”, that means the limit position has not been set by
the control board, please set the limit position refer to the chapter “setting of the control board”.
Summary of Contents for CASAR HJ4021
Page 6: ...3 Installation Overview Dual Gate Opener Parts List HJ4022...
Page 19: ...16...
Page 29: ...26 Quick Setting Guide...
Page 30: ...27...
Page 31: ...28...
Page 32: ...29...