Setting of the Control Board
WARNING: Ensure that the gate opener is Powered Off when you make any adjustment of the
gate opener. Keep away from the path of the gate during you set the gate opener system in case of
the unexpected gate moving. Carefully adjust settings to avoid the risk of machine damage and
injury or death. Always ask the help of professional technician /electrician if you have any question.
NOTE: The limit position must be set once complete installation or the power comes back after a
power outage.
1.
Check again for completed and correct assembly of your swing gate opener and gate. Power on the
gate opener, the Digital Display on the Control Board will flash with “- -”. The unit is in standby.
NOTE:
You can follow these steps to enter the setting menu, finish
all the setting program
, and then go
back to the stand-by state.
If you only need to adjust
one setting program
, press and hold “FUNC” button for more than 4 seconds.
The digital display will indicate “
P1
”, then press “FUNC” button repeatedly to get the
desired setting
program of “P?”
, then press the “INC” and “DEC” buttons to adjust correspondingly. When the setting is
finished, press the “FUNC” button repeatedly to store the data, until the digital display on the control board
flashes with “- -”, the unit goes back to the standby state.
2. Single/Dual Gate setting
Press and hold the “
FUNC
” button for more than 4 seconds. The Digital Display will indicate
“P1”
. Gate
opener is in SINGLE/DUAL Gate setting. Press the
“INC”
and
“DEC”
button respectively to following
modes:
“01” shown in Digital Display, it is Single Actuator 1 (Gate 1) mode. “10” shown in Digital Display, it is Single
Actuator 2 (Gate 2) mode. “11” shown in Digital Display, it is Dual actuator mode.
Press the “
FUNC
” button to store the data when the single or dual gate is chosen. The Digital Display will
indicate
“P2”
. Now single/dual gate set is finished.
(Factory default setting is “11”)
3. Set the limit position
NOTE: Before setting limit position, please install gate block in the desired position for opening or
closing as necessary.
NOTE: To operate the gate openers, please ensure limit position was learnt successfully first.
When Digital Display indicates
“P2”
, the gate opener will be in limit position setting mode.
Press the “
INC
” or “
DEC”
Button, the setting procedures will begin automatically.
Limit position automatic setting process is as follows:
<Single swing gate opener:>
The gate will open firstly till it retracts to the end (for PULL to OPEN) or pushes against the open limit gate
block tightly (for PUSH to OPEN) then stop. Next it will close automatically and stop at the close limit gate
block (for PULL to OPEN) or retracts to the end (for PUSH to OPEN). Finally, the gate will be back to open
status. Now the limit positions have been set successfully.
Gate open fully
Gate close fully
Gate open fully
limit position learning successfully.
<Dual swing gate opener :>
The master gate opener will open firstly till it retracts to the end (for PULL to OPEN) or pushes against the
open limit gate block tightly (for PUSH to OPEN) then stop. Then the slave gate opener will repeat the
same procedure. Next, the slave gate will automatically close and stop at the close limit gate block (for
PULL to OPEN) or retracts to the end (for PUSH to OPEN). Accordingly the master gate does the same.