16
Without a properly installed safety reversal system, person (particularly small children) could be SERIOUSLY INJURED
or KILLED by a closing gate.
*Too much force on gate will
interfere with proper operation of safety reversal system.
*NEVER
increase force beyond minimum amount required to close gate.
*NEVER use force adjustments to compensate for a binding or sticking gate.
*
If one control (force or travel limits) is adjusted, the other control may also need adjustment.
* After ANY adjustments are
made, the safety reversal system MUST be tested. Gate MUST BE TESTED. Gate MUST
reverse on contact with a rigid object.
The opener is equipped with an obstruction sensing feature. If the gate encounters an obstruction the opener will
automatically reverse direction and stop. Based on the length and weight of the gate it may be necessary to make force
adjustments. The force adjustment should be high enough that small objects such as branches or wind will not cause
nuisance interruptions but low enough to prevent serious injury to a person or a vehicle.
NOTE:
You may need to increase the stall force in cold weather due to increased resistance from
gate hinges. The gate opener’s opening/closing force is adjusted automatically according to stall force
adjustment.
Press the “FUNC” button to store the data when the close interval is set. The Digital Display will indicate “P5”.
Now Close Interval Set is finished.
6. Adjust the Obstruction Sensitivity/Stall Force
When the Digital Display indicates “P5”, the gate opener is on the Stall Force Adjustment.
6-a Adjust Stall Force of Gate Opener 1
Now we adjust the stall force of gate 1
The stall force of gate opener1 is adjusted by pressing “INC” and “DEC” buttons respectively. The Digital
Display will show “1”-“9” which indicates the stall force levels. “1” means the minimum force, and “9” is the
maximum force. Each time you press and release the “INC” button, the figure increase by 1, and the force
increases to a higher level. Each time you press and release the “DEC” button, the figure decreases by 1, and
the force decreases to a lower level. Press “FUNC” to store the data. The Digital Display will indicate “P6”.
Now stall force of gate opener 1 is finished.
(Factory set is Level 3)
6-b Adjust Stall Force of Gate Opener 2
When the Digital Display indicates “P6”.you can adjust force of gate opener 2.
Please perform the same procedure as gate opener 1 (6-a).
Press the “FUNC” button to store the data when stall force of gate opener 2 is set. Then “P7” will be shown on
the Digital Display.
7. Adjust the Max Motor Running Time (MRT) of the MOTOR for gate opener
The maximum running time of the MOTOR can be set to make the motor stop running after a specified period
even if the limit switch is invalid or the clutch is detached.
7-a. Adjust the MRT of MOTOR1
When the Digital Display indicates “P7”, you can adjust the
MRT
of MOTOR1.
The
MRT
of MOTOR1 is adjusted by pressing “INC” and “DEC” buttons respectively. The Digital Display will
show “01”-“50” which indicates the
MRT
of MOTOR1 from 1 to 50 seconds.
You can hold pressing the “INC” or “DEC” button for more than 1 second to speed up the setting. Press the
“FUNC” button to store the data when you finish setting. The Digital Display will indicate “P8”.
(Factory default setting is “40” seconds)
7-b. Adjust the MRT of MOTOR2
When the Digital Display indicates “P8”, you can adjust the
MRT
of MOTOR2.
Please perform the same procedure as adjusting MOTOR1 (7-a).
Press the “FUNC” button to store the data when you finish setting. The Digital Display will indicate “P9”. Now