background image

15 

Setting of the Control Board 

WARNING: Ensure the gate opener is Power Off when you make any adjustment of the gate opener. 

Keep away from the path of the gate during you set the gate opener system in case of the unexpected 

gate moving. Carefully adjust settings to avoid the risk of machine damage and injury or death. Always 

ask the help of professional technician /electrician if you have any question. 

1.

 Check again for completed and correct assembly of your swing gate opener and gate. Plug the Power Cord 

into the nearest AC outlet. The Digital Display on the Control Board will flash with “- -”. The unit is in standby. 

2. Single/Dual Gate Set 

Press and hold the “FUNC” button for more than 4 seconds. The Digital Display will indicate 

P1”. Gate opener 

is on the SINGLE/DUAL Gate setting. Press the “INC” and “DEC” buttons respectively to following modes: 

“01” shown in Digital Display, it is Single Actuator 1 (Gate 1) mode. “10” shown in Digital Display, it is Single 

Actuator 2 (Gate 2) mode. “11” shown in Digital Display, it is Dual actuator mode. 

Press the “FUNC”  button to store the data  when the single or dual gate is chosen. The  Digital  Display  will 

indicate “P2”. Now single/dual gate set is finished.   

(Factory set is “11”)

 

3. Set “PUSH TO OPEN” or “PULL TO OPEN” 

If the gate opens into the property (pull to open), the DIP Switch is set to OFF (factory default setting). If 

your gate opens out from the property (push to open) the DIP Switch must be set to the ON position. 

Factory default setting is OFF. 

When Digital Display indicates “P2”, the gate opener is on the 

PUSH/PULL TO OPEN

 Setting. Press the “INC” 

and “DEC” Buttons respectively to follow modes: 

“00” shown in Digital Display, which means gate opens into the property (pull to open). 

“11” shown in Digital Display, which means gate opens out from the property (push to open). 

Press the “FUNC”  button to store the data  when the master/slave gate is chosen. The  Digital  Display  will 

indicate “P3”. Now 

PUSH/PULL TO OPEN

 Setting is finished.   

(Factory set is “00”) 

4.  Set the Open Interval between Master and Slave Gate 

When the Digital Display indicates “P3”, the gate opener is on the Open Interval between Master/Slave Gate 

Setting. 

The open interval can be adjusted by pressing the “INC” and “DEC” Buttons respectively. The Digital Display 

will show “0”-“9”, which indicates the interval time “0” means the Master and Slave gates open simultaneously. 

“1” means the Master Gate starts to open 1 second before Slave gate starts to open. Max. open interval is 9 

seconds. Each time you press and release the “INC”  button, the  figure  increases by  1, and  the Master gate 

starts to open 1 more second earlier. Each time you press and release the “DEC” button, the figure decreases 

by 1, and the interval decreases by 1 second. 

(Factory set is 3 seconds) 

Press the “FUNC” button to store the data when the open interval is set. The Digital Display will indicate “P4”. 

Now Open Interval Set is finished. 

5.  Set the Close Interval between Master and Slave Gate   

When the Digital Display indicates “P4”, the gate opener is on the Close Interval between Master/Slave Gate 

Setting. 

The close interval can be adjusted by pressing the “INC” and “DEC” buttons respectively. The Digital Display 

will show “0”-“9”, which indicates the interval time ”0”  means  the Master and Slave gates close 

simultaneously. ”1” means the Slave Gate starts to close 1 second before Master gate starts to close. Maximum 

close interval is 9 seconds. Each time you press and release the “INC” button, the figure increases by 1, and the 

Slave gate starts to close 1 more second earlier. Each time you press and release the “DEC” button, the figure 

decreases by 1, and the interval decreases by 1 second. 

(Factory set is 3 seconds) 

Summary of Contents for AT602

Page 1: ...VER 20a AT602 Please read and follow all warnings precautions and instructions before installation and use Never connect the solar panel to the control board directly to charge the battery Periodic ch...

Page 2: ...on for Installation 6 Install the Gate Opener on the Gate 6 Mounting the Control Box 10 Connection of Power Supply 11 Connecting of the Control Board 11 How to Program or Erase the Remote 13 How to Us...

Page 3: ...destrian access shall be located such that persons will not come in contact with the moving vehicular gate 8 Pedestrians should never cross the pathway of a moving gate The gate opener is not acceptab...

Page 4: ...er or other underground utility lines contact underground utility locating companies BEFORE digging SAVE INSTRUCTION 14 Do not permit children to play on or around the gate and keep all controls out o...

Page 5: ...Accessories Parts List Available at TOPENS Store Tools Needed Power Drill Tape Measure Open End Wrenches 14 17 or Adjustable Wrenches Wire Strippers C Clamps small medium and large Level Hacksaw or He...

Page 6: ...al Single gate running mode Adjustable opening closing interval between master and slave gate Stop in case of obstruction during gate opening Reverse in case of obstruction during gate closing Built i...

Page 7: ...n Overview Pull to Open Gates Important The second gate opener cable should be put into the PVC conduit not provided which is buried underground This protects the cable from lawn mowers and string tri...

Page 8: ...ckets to wooden posts a larger size washer or metal plate should be used between the bolts and the wooden post to ensure the stability of the fastening hardware If the post is smaller than 6 diameter...

Page 9: ...te opener insert the release key and turn the key 90 clockwise This releases the motor and allows the push pull rod to be manually extended and retracted To restore normal operation turn the key 90 co...

Page 10: ...f there is not at least 2 5cm of clearance or if the opener and the Post Pivot Bracket are binding rotate the Post Pivot Bracket and or move the Post Bracket Assembly to obtain the minimum clearance a...

Page 11: ...ach bolt with one 10 washer one 10 lock washer and one 10 nut 9 Attach the gate brackets to each gate by inserting two M10 x 75 bolts through the gate brackets and the drilled holes in the gates Faste...

Page 12: ...s waterproof designed for safety reason and a longer service life it is recommended to install the control box inside a secure surface and at least 100 cm 40 inches above the ground to avoid being flo...

Page 13: ...awn mowers weed eaters and grazing animals 4 The fuse in the control board is interchangeable A 10a 250vac 5 20mm fuse is suitable to the control board Connecting of the Control Board Actuator 1 Inser...

Page 14: ...12...

Page 15: ...LACK wire of the external receiver should be connected into the 16 terminal The RED wire of the external receiver should be connected into the 13 terminal Wired Keypad 24VDC optional The RED wire of t...

Page 16: ...e Button B is designed to realize midway function refer to more details in our TOPENS sliding gate opener manual So it is must program button A with sliding gate opener while you may program either C...

Page 17: ...ital Display which means gate opens out from the property push to open Press the FUNC button to store the data when the master slave gate is chosen The Digital Display will indicate P3 Now PUSH PULL T...

Page 18: ...is adjusted by pressing INC and DEC buttons respectively The Digital Display will show 1 9 which indicates the stall force levels 1 means the minimum force and 9 is the maximum force Each time you pr...

Page 19: ...iod of soft start You can press the INC or DEC button to set the period of soft start There is 1 9 seconds available in setting Press the FUNC button to store the data when the period is set The Digit...

Page 20: ...ar the actuator retracts It will retract to the end when using Adjust Limit switch B to decide how far the actuator 2 extends Use a screwdriver to loosen the screw of Limit Switch B slide Limit Switch...

Page 21: ...ff and allow transformer to cool for several minutes then reset Replace the transformer if the symptom still exists 3 Check the fuse in the control board Replace the fuse if necessary Opener powers up...

Page 22: ...UE GREEN YELLOW wires of the arm are not shorted 2 Limit switch of the arm is faulty Replace the limit switch as necessary Gate opens closes or stops on its own 1 Please make sure the P2 setting of th...

Page 23: ...21 Quick Setting Guide...

Page 24: ...22...

Page 25: ...23...

Page 26: ...24...

Page 27: ...e do not hesitate to contact us E mail support topenstool com Kindly include your Product Model Purchasing Date Site Order and your contact information All your concerns will be replied within 24 hour...