18
NOTE:
The Obstruction Sensitivity /Stall Force is adjustable in 9 levels.
Indicate Illustration on the Digital Display When Gate Opener is Running
The left image on Digital Display symbolizes motor of gate opener 2 when the gate opener is running. The right
image on Digital Display symbolizes motor of gate opener 1.
When the motor is run to gate -open direction or gate -close direction, the image on Digital Display indicates “n”
or “u” respectively.
When the motor is not running, the Digital Display indicates
“- -”.
Adjusting the Limit Switch
Adjusting the Limit Switch of Actuator 1
There is no limit switch for adjusting how
far the actuator retracts. It will retract to the
end when using. Adjust Limit switch A to
decide how far the actuator 1 extends.
Use a screwdriver to loosen the screw of
Limit Switch A, slide Limit Switch A and
operate the gate opener to test if it meets
your desired position. Fix the limit switch after testing.
Limit setting for Gate 1 is finished now.
Adjusting the Limit Switch of Actuator 2
There is no limit switch for adjusting how
far the actuator retracts. It will retract to the
end when using. Adjust Limit switch B to
decide how far the actuator 2 extends.
Use a screwdriver to loosen the screw of
Limit Switch B, slide Limit Switch B and
operate the gate opener to test if it meets
your desired position. Fix the limit switch
after testing.
Limit setting for Gate 2 is finished now.
How to Operate
The user may operate the opener once all adjustment setting is finished.
With the gate in its closed position, press and release the remote control, the gate will move to the programmed
opening position and stop.
With the gate in its opened position, press and release the remote control, the gate will move to the programmed
closing position and stop.
While the gate is moving, press and release the remote control, the gate will stop moving immediately. The next
command from the remote will reverse the gate direction and the gate will stop at its programmed opening/closing
position.
The gate will stop in case of obstruction during opening. The command from the remote control will reverse the
gate direction and the gate will stop at its programmed closing position.
The gate will reverse in case of obstruction or stall force during closing, and it will move to the programmed