Imported by SEA S.p.A.

Zona industriale 64020 S.ATTO Teramo - (ITALY)

Tel. +39 0861 588341 r.a. Fax +39 0861 588344

www.bleuteam.it 

[email protected] 

REV 00 - 12/2014

INSTALLATION MANUAL

B 100 PLUS

600N

 B 100 PLUS 

1000N

Summary of Contents for B 100 PLUS 1000N

Page 1: ...r garage doors Imported by SEA S p A Zona industriale 64020 S ATTO Teramo ITALY Tel 39 0861 588341 r a Fax 39 0861 588344 www bleuteam it info bleuteam it REV 00 12 2014 INSTALLATION MANUAL B 100 PLUS 600N B 100 PLUS 1000N ...

Page 2: ... 9 4 6 MOUNT OPENER TO CEILING 9 4 7 CONNECTARM TO DOORAND TROLLEY 10 4 8 CHECK EMERGENCY RELEASE 10 4 9 TENSION ADJUST 11 4 10 RAILINSTALLATION 11 5 CONTROL UNIT 12 5 1 SAFETY AND CONTROL DEVICES CONNEXION 13 5 2 CONTROL UNIT PROGRAMMING 13 5 3 TRANSMITTERS MEMORIZATION 13 5 4 RUN LEARNING 14 5 5 THE ADJUSTMENT OF REVERSE FORCE 1 4 5 6 USE PHOTOELECTRIC SWITCHES 15 5 7 USE AUTOMATICALLY CLOSING F...

Page 3: ...s a slow starting movement of the door Soft stop With the aid of this function the opener can slow down before reaching the final position Logic OPEN STOP CLOSE STOP OPEN Additional connecting options for external accessories In addition you can connect up external push buttons such as internal buttons key switches and a wicket door contact Profile slide carriage Closed end position Open end posit...

Page 4: ...nism is attached to the profile slide with a rope and a knob By pulling the rope you uncouple the garage door from the opener and then you can open the door by hand It is suggested to Close or open the door fully after each release The emergency release is not intended for everyday use since it is an emergency device Internal release mechanism English Rail and operators size REV 00 12 2014 4 ...

Page 5: ...er and rail are packaged with their respective carton English A OPENER B ACCESSOIRES a Wall Bracket 1x b D oor Braket Plate 1x c U Bracket 3x e Clevis 1x f Clevis 1x g Cotter pin 3x h Hex nut 1x i Hex bolts 1x k Hex Head Driving Screw 4x C Straight DoorArm D Curved DoorArm F Rail REV 00 12 2014 5 ...

Page 6: ...irs to garage door cables spring assemblies and other hardware before installing the opener 4 Remove all ropes and disable all locks connected to the garage door before installing opener 6 After installing the opener test Safety Reversal System Door MUST reverse when touching an obstacle within the time and ways described in the regulations English 5 Do not connect the opener source of power until...

Page 7: ... garage floor to the top of door Write down this distance Add 30mm to the door travel height measured above English 4 2 Install header bracket WARNING If the header bracket is not rigidly fastened to a sound structural support on the header wall or ceiling the safety reverse system may not work and could cause accidents and serious injuries DO NOT move or adjust springs or garage door hardware as ...

Page 8: ...ng and causing damage to persons or property in the garage Position rail onto opener chassis by lining up rail sprocket opening with motor head shaft see drawing 4 4 1 Make sure shaft engages teeth inside rail sprocket Position 2 C rail clips over rail and onto chassis Flanges on C rail clips MUST fit into guide posts recesses see drawing 4 4 2 English Insert screws k through bracket holes and int...

Page 9: ...t opener to ceiling WARNING If not properly secured the operator could fall and injure someone Secure opener to structural supports or framing Do not mount to drywall plaster or other such material Position opener head so that rail is lined up with center line of open door Line up hanger brackets not provided with ceiling joists or framing to locate where brackets are to be fastened With two screw...

Page 10: ...th red knob which is already attached to the trolley is extremely important parts of the operator system see drawing 4 7 1 pulling the release cord disengages the door from the opener This allows the door to be moved manually up and down independent of the opener motor If the door is in the open position use extreme care when using the release Use emergency release to disconnect the door if the po...

Page 11: ...e right position English 4 10 Rail installation 1 2 Rail end 3 4 Rail 5 Slider 6 B 7 8 9 chain 10 11 12 13 14 15 16 17 18 Lock nut Party neck bolt lock Self tapping screws spring Pulley block Slippery wheel pulley bars Shake hands handle Spring Link head Sprocket stents Sprocket REV 00 12 2014 11 ...

Page 12: ...ND PBSW Allarm A SW CN1 Input output connector CNE Encoder connector CNR External receiver connector SD Door contact MR Right motor ML Left motor POWER Power supply connector BATTERY Battery connector LIGHT Courtesy light connector DISPLAY Display connector English REV 00 12 2014 12 ...

Page 13: ...isplay If the numbers appear reversed immediately press the button setting and the numbers will be reversed and displayed in the correct manner Press and keep pressed CODE until the decimal point is bright and then off automatically Release CODE all memories are erased 1 Press CODE over one second until the LED display dot is brightened Press any button of remote control once the decimal point is ...

Page 14: ...in the desired closed position During this phase the display displays the letter u When the door reaches to the desirable position leave press SETTING to confirm the closing position After finishing setting the LED will display ll and the door can operate normally NOTE and the door moves in closing exchange the motor cables If press button Press SETTING until the LED displays the letter 3 and rele...

Page 15: ...D displays you can set Automatically closing function Press OPEN or CLOSE to adjust automatically closing time When set up is completed press SETTING to confirm and exit E m e r g e n c y s t o p connection It is possible to connect on the CN2 terminal a battery f o r t h e e m e r g e n c y operation Connect a 12V max 2Ah battery charge current 150mA The closing time will vary from 1 to 9 min in ...

Page 16: ...n the middle on its way or runs at opposite way The door operating resistance is stronger than the set force Check the balance system of the door Readjust the opener to increase the load force of the door The door cannot be closed The photoelectric switch is sheltered from the obstacle The photoelectric is not connected Remove the obstacle Connected the photoelectric The door cannot be opened or c...

Page 17: ...he automated system s security and efficiency if components used are not produced by BLEU by SEA 10 For maintenance strictly use original parts by BLEU by SEA 11 Do not modify in any way the components of the automated system 12 The installer shall supply all information concerning system s manual functioning in case of emergency and shall hand over to the user the warnings handbook supplied with ...

Page 18: ...roduct within the field of applicability of the following Community Directives Direttiva 2006 42 CE Direttiva macchine allegato I Directive 2006 42 CE Machinery Directive annex I Direttiva 2004 108 CE Direttiva compatibilità elettromagnetica Directive 2004 108 CE Electromagnetic compatibility CEI EN55014 1 Emissioni condotte e radiate IEC EN55014 1 Conducted and radiated emissions CEI EN55014 2 Pr...

Page 19: ......

Page 20: ...Imported by SEA S p A Zona industriale 64020 S ATTO Teramo ITALY Tel 39 0861 588341 r a Fax 39 0861 588344 www bleuteam it info bleuteam it ...