background image

 

32 

PROUD MANUFACTURERS & SUPPLIERS OF: 

 

SLIDE GATE OPERATORS: 

• 

COMPACT 300 

• 

COMPACT 500 

• 

SOLO 

• 

CONDO 

• 

CONDO AC/DC 

 
SWING GATE OPERATORS: 

• 

DURASWING 

 
GARAGE DOOR OPERATORS: 

• 

LAZER SECTIONAL 

• 

LAZER ROLL UP 

• 

LAZER VERTICAL ROLL UP 

• 

LAZER TIP UP 

 
TRANSMITTER & RECEIVERS: 

• 

DURATRONIC 2; 3; 4 & 6 BUTTON REMOTES 

• 

DURATRONIC On-BOARD & EXTERNAL RECEIVERS 

 
SAFETY BEAMS: 

• 

DURAOPTICS 

 
VEHICLE DETECTION LOOP: 

• 

DURALOOP 

www.dace.co.za ● [email protected] 

 

  

INSTALLATION AND OWNERS MANUAL 

DURASWING 

GATE OPERATORS

GATE OPERATORS

GATE OPERATORS

GATE OPERATORS    

www.dace.co.za ● [email protected] 

Summary of Contents for DURASWING

Page 1: ...ZER ROLL UP LAZER VERTICAL ROLL UP LAZER TIP UP TRANSMITTER RECEIVERS DURATRONIC 2 3 4 6 BUTTON REMOTES DURATRONIC On BOARD EXTERNAL RECEIVERS SAFETY BEAMS DURAOPTICS VEHICLE DETECTION LOOP DURALOOP www dace co za info duraproducts co za INSTALLATION AND OWNERS MANUAL DURASWING GATE OPERATORS GATE OPERATORS GATE OPERATORS GATE OPERATORS www dace co za info duraproducts co za ...

Page 2: ...epair or replacement The transport cost is for the end users account If the equipment was purchased at a dealer merchant or agent of D A C E the claim must be directed to said merchant dealer etc The warranty will not cover any of the following circumstances in any way Incorrect installation of the equipment Incorrect wiring of the equipment Lightning flooding power surge fire corrosion insect inf...

Page 3: ...it is recommended that an external DuraTronic receiver be used This automatic gate operator is NOT a security device It is designed to make access to a premises undemanding SPECIFICATIONS LEGAL REQUIREMENTS AND WARNINGS Motors 12v dc battery operated with charging system Maximum gate size 2 5 m per leaf Maximum gate mass 100 kg per leaf Maximum number of operations 100 per day Maximum operating de...

Page 4: ...m of 1 5mm cable DO NOT use communications cable Main PC Board this is the printed circuit board that contains all the electronic components that operate the operator NOTE Always remove the power from the PC board before con necting any out put wires Receiver receives a signal from the transmitter and triggers the operator Remote Transmitter usually a hand held product which transmits a signal to ...

Page 5: ...l pillar light LIGHT LOCK BOARD WHITE PURPLE BLACK RED 12v red GND black LIGHT white LOCK purpl Toggle LIGHT OUT LOCK OUT IMPORTANT Use separate power supply 5 All cabling should be in conduit a minimum of 300 mm underground Ensure that any high voltage 230V cables are run in separate conduit The transformer should be placed inside the house and then 16 VAC run to the charger module in the operato...

Page 6: ...he manufac turers specifications before installing a magnetic lock In order for the magnetic lock to operate on the DuraSwing gate motor a D A C E Mag Lock Card SA141 must be connected to the main PC Board The Mag Lock card will delay the opening of one leaf of the gate for 2 seconds The power supply to the Mag Lock must not be taken from the motor battery or the PC Board as this will result in a ...

Page 7: ...take the board to a recognized D A C E dealer for any repairs needed ELECTRICAL WIRING If the intention is to run 230V high voltage to the motor it is strongly recommended that the local E C A Electrical Contractors Association is contacted in the area before any wiring is done to obtain the local requirements regarding electrical wiring regulations Running 230V must be done by a regis tered elect...

Page 8: ...onduit is waterproof Do not use communication type cable for the power supply Do not join cables underground Failure to wire the transformer correctly will result in the transformer being damaged DANGER HIGH VOLT AGE 220 V AC IN PUT Transformer Main PC Board EARTH 16 VAC Master Motor Transformer power supply 16 volts output to PC Board 230 V Input 300 mm Recommended distance 50 m 25 WIRING ONE SET...

Page 9: ...icient The DuraTronic external receiver can hold 128 remotes The DuraTronic receiver should be mounted outside the operator housing for increased range CONNECTOR BLOCKS ON MAIN PC BOARD GND PED LED STAT INF LOOP 12 24V TRIG 12 24 COM N O N C NEG CONNECTOR BLOCKS ON EXTERNAL RECEIVER 9 MOUNTING THE OPERATORS The operators can be mounted either as a Wall Mount and Pedestal Mount The diagrams below s...

Page 10: ...ercurrents This means that if the gate hits an object or is obstructed it will see an increase in the current and the gates will stop driving The results of the detected overcurrent will be different depending on what the gate is doing at the time of the overcurrent If the gate is closing and an overcurrent is detected the gate will stop and then re open If the gate is opening and an overcurrent i...

Page 11: ...ill stop working This LED must be on at all times OPEN this LED is on when the gate is opening or is in the open position CLOSE this LED is on when the gate is closing or is in the closed position REV this LED flashes when the motor operates for slide gate operators only LOW BATT this LED indicates that the battery is low or flat This is a red LED and will flash continu ously until the battery is ...

Page 12: ... 70 seconds Auto close is selected by using the dipswitches on the main PC Board Dipswitch numbers 6 7 and 8 are the auto close time select switches The times are as follows 6 off 7 off 8 off no auto close 6 on 7 off 8 off 10 seconds 6 off 7 on 8 off 20 seconds 6 off 7 off 8 on 40 seconds 6 on 7 on 8 on 70 seconds Any combination can be used to select the desired auto close time It is strongly rec...

Page 13: ...con nected to the GND connector The remote LED will give the same indication as the STATUS LED on the PC Board 12 24V This connector is used to supply power to auxiliary equipment used i e intercom receiver infrared beams etc This output has a resettable fuse for protection see wiring diagrams for more details on wiring auxiliary equipment This is not to be used to power up a Magnetic Lock or Stri...

Page 14: ...t with erasing any lost or stolen remote at a later stage Step 1 press and hold the button that is to trigger this application on the remote It is important that this button is continuously held from step 1 through to 3 Step 2 place the jumper over the two pins on the PC Board called TX L for 2 seconds Step 3 remove the jumper from the two pins Step 4 release the button on the remote That particul...

Page 15: ... rotor The rotor can be removed com pletely to assist with the set up 5 6 7 15 WALL MOUNT OUTWARD SWING All OUTWARD swing installations require SHORT crank arms and LONG conrods When outward swing gates are setup the operators will protrude into the driveway by 155mm on each side of the driveway Any attempt to mount the operators in any other manner will cause operational problems with the gates G...

Page 16: ...have to establish the closing direction of the operators The operators should automatically drive to the closed position when first powered up but as each site is unique it may not Apply power to the motor and take note of the direction that the shaft turns NOTE If it is determined that the operators are turning the correct way continue to set up the limit switches as shown below If the operators ...