57
13. DISTANCE MEASUREMENT
PROCEDURE
1. Accurately sight the target.
2. Press
[S-LEV]
in Observation mode.
<Aiming> is displayed.
Allocating
[S-LEV]
When
[S-LEV]
is pressed, a gauge indicating light
intensity is displayed.
• The more
displayed, the greater the
quantity of reflected light.
•
If “
” is displayed, only enough light for the
measurement is returned.
•
When “
” is not displayed, accurately resight
the target.
[BEEP]/[OFF]
: Sets a buzzer sound when
measurement is possible. Press to switch on
and off.
[MEAS]
: Returns to Observation mode and
starts angle and distance measurement.
3. Press
[OFF]
to finish signal checking.
Press
{ESC}
or tap the cross in the top-right
corner to return to the previous screen.
• When
is displayed persistently, but “
” is not, contact your local dealer.
• If no key operations are performed for two minutes, the display automatically returns to the previous
screen.