97
18.MISSING LINE MEASUREMENT
Missing line measurement is used to measure the slope distance, horizontal distance, and horizontal
angle to a target from the target which is the reference (starting point) without moving the instrument.
• It is possible to change the last measured point to the next starting position.
• Measurement results can be displayed as the gradient between two points.
• It is possible to allocate softkeys in measurement menus to suit various applications and the ways
that different operators handle the instrument.
"20.6 Allocating Key Functions"
PROCEDURE
1. Select "MLM" in <Menu>.
18.1
Measuring the Distance between 2 or more Points