14. COORDINATE MEASUREMENT
64
PROCEDURE Entering coordinates
1. Select "Backsight setup" in <Coordinate>. <Set
H angle> is displayed.
• <Set H angle> can also be displayed from the
screen in step 4 of "14.1 Entering Instrument
Station Data".
2. Select the "Key in coord" tab and enter the
backsight station coordinates.
• When checking backsight distance, sight the
backsight station and press
[MEAS]
. Press
[STOP]
to display the distance calculated from
coordinates, the measured distance, and the
difference between the two. Press
[YES]
to set
the azimuth angle and display <Coord.
measurement>.
•
[Azimuth]
: Switches horizontal angle setting
method.
3. Press
[OK]
to set the azimuth angle. <Coord.
measurement> is displayed.