119
20. CHANGING THE SETTINGS
3. "SHV" and "NEZ" tabs of <Set out Coords>
Page 1
[ OK ] [ --- ][CNFG] [MEAS]
Page 2
[ --- ] [ --- ] [ --- ] [ --- ]
Page 3
[ --- ] [ --- ] [ --- ] [ --- ]
The following functions can be allocated to the softkeys.
[ --- ]
: No functions set
[MEAS]
: Distance and angle measurement
[CNFG]
: Set setting out accuracy (can only be allocated to 2 and 3 above)
[SHV]
: Switch the "SHV" tab and "SHVdist" tab (can only be allocated to 1 above)
[SHVR]
: Switch distance mode between slope distance (SD)/horizontal distance (HD)/height
difference (VD)/REM (R) in setting out screens. The capitalized letter in the softkey
indicates the currently selected mode (can only be allocated to 2 above).
[OK]
: Terminate setting out measurement for the selected setting out point and return to
<Key in coord>. This setting out point will be removed from the list (can only be
allocated to 3 above).
[0SET]
: Set horizontal angle to 0°
[H-SET]
: Set required horizontal angle
[R/L]
: Select horizontal angle right/left. The capitalized letter in the softkey indicates the
currently selected mode.
[ZA / %]
: Switch between zenith angle/slope in %. The capitalized letter in the softkey indicates
the currently selected mode.
[HOLD]
: Hold horizontal angle/release horizontal angle
[CALL]
: Display final measurement data
[HVOUT-S]
: Output angle measurement results to an external device (SET format)
[HVDOUT-S]
: Output distance and angle measurement results to an external device (SET format)
[NEZOUT-S]
: Output coordinates data to an external device (SET format)
[HVOUT-T]
: Output angle measurement results to an external device (GTS format) (can only be
allocated to 1 above)
[HVDOUT-T]
: Output distance and angle measurement results to an external device (GTS format)
(can only be allocated to 1 above)
[NEZOUT-T]
: Output coordinates data to an external device (GTS format) (can only be allocated to
1 above)
[F/M]
: Switch distance units between meters/feet
[HT]
: Set the instrument station, coordinates and instrument height
[S-LEV]
: Return signal
[TILT]
: Display tilt angle
[EDM]
: EDM settings
[MENU]
: Display <Menu> (coordinate measurement, setting out measurement, offset
measurement, REM measurement, missing line measurement, resection, area
calculation)
[COORD]
: Coordinates measurement
[S-O]
: Setting-out measurement
[OFFSET]
: Offset measurement
[A-OFS]
: Angle offset measurement
[D-OFS]
: Distance offset measurement
[2D-OFS]
: Offset/2D measurement
[MLM]
: Missing line measurement
[REM]
: REM measurement
[RESEC]
: Resection measurement
[AREA]
: Surface area measurement