PLS-601 User's Manual
Document #11696 Page - 35
4.2.8 COPY Function - Continued
The COPY function and ‘U’ option must be selected on BOTH units before a SEND or RECEIVE
selection is made on either. Failure to follow this sequence will result in a ‘RECEIVE LINE ERR’
being displayed on the RECEIVE UNIT.
4.2.9 SPECIAL FUNCTION - F7
The F7 function key can be used to implement a special function, as required by a specific user
application.
4.2.10 SPECIAL FUNCTION - F8
The F8 function key can be used to implement a special function, as required by a specific user
application.
4.2.11 END
The END function is used to end data entry for the current PROGRAM, and allows selection of
any one of the four PLS-601 PROGRAMS for data entry.
The Transducer shaft POSITION (‘P’) and the shaft SPEED in RPM (‘R’) are displayed.
After entering the PROGRAM NUMBER, the FUNCTION LED is lit indicating that one of the
ten PLS-601 functions may be selected.
Select
END
Selects the END function
New Display
PROG
1
P140 - R030
Select:
DATA 1 - 4
The numerical value of the selected DATA KEY is
displayed in the ‘PROG’ field.
Select
INC
Increments the displayed PROGRAM NUMBER
Select
DEC
Decrements the displayed PROGRAM NUMBER
Select
CLEAR
Sets the displayed PROGRAM NUMBER to 1.
Select
ENTER
Selects the displayed PROGRAM NUMBER for
data entry, Turns on the FUNCTION LED.
4.3 OUTPUT DISABLE
The OUTPUT DISABLE key provides the capability of enabling or disabling the RELAY outputs
(see section 3.4) without affecting the Channel outputs (see section 3.2.5). When lit, the associated
OUTPUT DISABLE LED indicates that the Relay outputs have been disabled.
NOTE: OUTPUT DISABLE does not disable the Relay 16 output when RELAY 16 JUMPER
OPTION “S” has been selected (See section3.4.1.4 for details of the RELAY 16 JUMPER
OPTION).