PLS-601 User's Manual
Document #11696 Page - 26
4.2.7 TEACH Function
The TEACH function allows a user to enter the CURRENT SHAFT POSITON into memory as
the FROM or TO position of a LOBE - using only the ENTER key.
TEACH Function:
Select:
TEACH
Selects the TEACH data entry function.
New Display
:
CH
A
01 F -T
(Highlighted character indicates blinking character that can be changed.)
To enter LOBE data, the CHANNEL GROUP must be selected. Once the channel group has been
chosen, the desired channel within the group must be selected. The channels are divided into four
groups with each group consisting of up to sixteen channels. When all channel groups are active, a
total of 64 individual channels become available. The channels are designated as A01 - A16, B01 -
B16, C01 - C16, and D01 - D16.
SELECTING THE CHANNEL GROUP:
Display:
CH
A
01 F -T
(Highlighted character indicates blinking character that can be changed)
Select:
INC
Increments the active group (A, B, C, or D) to the next
available group value.
New Display
:
CH
B
01 F -T
Select:
DEC
Decrements the active group (A, B, C, or D) to the
previous available group value.
New Display
:
CH
A
01 F -T
Select:
<
CURSOR
Moves the cursor left in the three digit CHANNEL
field of the front panel display.
>
CURSOR
Moves the cursor right in the three digit CHANNEL
field of the front panel display.
Select:
CLEAR
Sets the displayed CHANNEL GROUP to ‘A’ and the
CHANNEL NUMBER to ‘1’.
New Display
:
CH
A
01 F -T
Select:
ENTER
Selects the displayed CHANNEL GROUP and
CHANNEL NUMBER for entry of LOBE DATA.
Select:
FUNCTION:
Terminates the TEACH function and returns the user to
FUNCTION select mode where any one of the PLS-601
functions can be selected.