19
Problem
Possible Causes
Solutions
Slow Drift Down 1. Mechanical safety locks not
engaged
2. Powerpack lowering valve
contamination
3. Hydraulic system leaks
1. Raise lift to engage all safety locks then lower lift
and confirm all safety locks are engaged
2. Back flush powerpack by opening manual over-
right valve. Engage "up" switch and down lever at
the same time and run approximately 10 seconds
3. Check cylinder and all fittings for any hydraulic oil
leak
Lift Going Up
Out ofLevel
1. Lift installed on un-level floor
2. Cable(s) out of adjustment
1. Reinstall on level surface
2. re-adjust cables - Call service technician if
problem persists
Anchors Will Not
Stay Tight
1. Holes drilled oversize
2. Concrete floor thickness or
holding strength not sufficient
1. Relocate lift using the correct bit to drill holes
2. Break out old concrete and re-pour new
foundation per lift installation instruction
Call factory for technical assistance if lift becomes inoperative in the raised position, and the
maximum operating hydraulic pressure developed upon lifting the rated capacity.
Replace all worn or broken parts and components only with
manufacturer approved/supplied parts and components
Replacement parts may be purchased from your local lift supplier or
the manufacturer at: 1-877-799-LIFT(5438) or (905) 847 – 1198
Summary of Contents for TLS430FDCEx1 Series
Page 23: ...23 Diagram 2 Front Crossmember...
Page 25: ...25 Diagram 3 Rear Crossmember...
Page 29: ...29 Diagram 6 Lifting Cable Routing...
Page 32: ...32 Diagram 8 Anchor Bolt Installation...
Page 33: ...33 Diagram 9 Driver Side Runway Assembly...
Page 41: ...41 Diagram 17 Power Unit Wiring Diagram...