72
Work on the product
Lubrication
TK Elevator
BA, TW45C | 6231003860 | 06/2022
Lubricant
Replacement interval
Motor position/filling
quantity
then every 8 years
horizontal approx. 4.0
litres
Tab. 21
ATR_1_21_0024_0
WARNING
Danger of scalding
Long-term car operation heats up the oil!
During work on the drive, wait until the housing has cooled down, if ne-
cessary.
1. Heat the gear to operating temperature (approx. 35°C) before replacing.
2. Drain off the gear oil by removing the cap on the oil drain pipe.
3. Collect the old oil in a container specifically designed for the purpose.
4. Empty the gear and close off the oil drain pipe with d-PTFE sealing tape.
Check for leakage.
5. Remove the red locking screw "OIL" and fill the gear housing until the pre-
scribed oil quantity is reached.
6. Check the level at the oil gauge glass.
7. Never mix different types of oil
8. Do not dispose of oil where it can enter the groundwater.
9. Dispose of old oil as well as cloths contaminated with oil and grease ac-
cording to prevailing regional regulations.
10. Use the gear oil SM1 approved by TK Aufzugswerke GmbH.
11. TK Aufzugswerke GmbH will not be held liable for damage resulting from
the use of non-approved lubricants.
Vertical motor position
1
4
5
6
7
8
2
3
Fig. 42
ATR_2_12_0317_0