68
Installation
Electrical connection
TK Elevator
BA, TW45C | 6231003860 | 06/2022
6.6.2
Connecting the motor line
1. Strip the insulation from the connection line.
2. Route cable through the cable gland.
3. Connect the PE conductor to the screwed connection specifically de-
signed for the purpose.
4. Connect the three motor wires to the terminals U, V and W as specified in
the terminal connecting plan.
5. Pull the shielding braid evenly over the lamellar insert.
6. The braid must not protrude beyond the lamellar insert into the thread.
7. Pull the cable through the cap nut.
8. Push the cap nut over the shielding.
9. Tighten the cap nut with the recommended torque in accordance with
manufacturer documentation
.
2
1
3
4
Fig. 38
ATR_2_21_0055_0
Item Designation
Item Designation
1
Cable with shielding braid
2
Lock nut
3
Lamellar insert
4
Cap nut
6.6.3
Connecting the posistor
NOTICE
Overvoltage at the measuring device!
Defective measuring device.
Do not apply a voltage greater than 2.5 V.
A triggering device (motor protection device) is required for evaluation of the
posistor temperature sensor installed in the motor.
1. Strip the insulation from the connection line.
2. Connect both wires in accordance with the terminal connecting plan.
3. Tighten the cap nut with the recommended torque in accordance with
manufacturer documentation
,
6.6.4
Connecting the brake
Brake connection, make: Mayr
Connect the brake (coil and microswitch) via the motor terminal box
.