TIVERTON AUDIO ELEMENT Elite Owner'S Manual Download Page 4

3

UNPACKING

  your ELEMENT PEMF System

After opening the carton, if possible keep the outer box,foam 

and fiber packing, and plastic bag. It’s handy for moving or in the 
unlikely event that your ELEMENT would need service or repair.

In the carton you will find:

ELEMENT Chassis.

 Though one of the most powerful units on

 

the market, the chassis is one of the smallest in size. This will

 

allow you to have the unit set up and ready to use at all times,

 

since it will comfortably fit on a nightstand or end table.

ELEMENT Coil

s

.

 

Their

 advanced design is engineered to make 

the

 

most of the chassis’s power and abilities. Made slightly oval 

to

 

better fit over the head, and slightly curved to better comfort-

ably contour to the body, 

they

 will deliver the magnetic field

 

where

 

you want it and at the levels you need it. The Coil

s

 come

 

with removable, washable cover

s

 that also helps provide

 

padding.

 

The 140-inch connecting cable allows you to use Coil

up to

 

ten feet or more from the ELEMENT chassis.

12-foot audio cable

 for connecting your remote source device

 

to

 

the input of the ELEMENT chassis. The ¹⁄

8

" stereo plugs are

 

compatible with the outputs of most source devices. You will

 

need an inexpensive, Apple Lightning

®

-to-¹⁄

8

" headphone

 

adaptor for newer iPhone

®

s.

AC Power Cable.

PLACEMENT

  of your ELEMENT PEMF System

• Use the front panel carry handle

to transport the ELEMENT chassis.

• The ELEMENT chassis should be

placed on a sturdy, well-supported
surface such as a table or night stand.
Be sure that the coil-to-chassis cord will reach to where you are
comfortable using the coil for extended periods of time.

• Make sure the back of the chassis is not closer than 1" from a

wall to avoid blocking the cooling fans' air flow.

4

UNPACKING

your ELEMENT Elite PEMF System

After unpacking your ELEMENT Elite, if possible keep the outer 
box, foam packing, and plastic bag. It’s handy for moving or in the 
unlikely event that your ELEMENT Elite would need to be returned 
to us for service or repair.  In the carton you will find:

 

ELEMENT Elite Chassis. One of the most powerful units on the 
market, the chassis is also one of the smallest in size. This allows 
you to have the unit set up and ready to use at all times, since it 
will comfortably fit on a nightstand or end table.

 

ELEMENT Elite Coils. Their advanced design is engineered to 
make the most of the chassis’s power and abilities. They will 
deliver the magnetic field where you want it and at the levels you 
need it. The Coils come with removable, washable covers that also 
help provide padding. The twelve-foot coil lead wires allow you to 
use coils up to ten feet or more from the ELEMENT Elite chassis.

 

12-foot audio cable for connecting your remote source device to 
the input of the ELEMENT Elite chassis. The ¹⁄

8

" (3.5mm) stereo 

plugs are compatible with the outputs of most source devices. 
You will need an inexpensive, Apple Lightning

®, 

or USB C-to-

¹

8

headphone adapter for newer iPhone

®

s.

 

AC Power Cable.

PLACEMENT

of your ELEMENT Elite PEMF System

 

The ELEMENT Elite chassis should be placed on a sturdy, well-
supported surface such as a table or night stand. Be sure that the 
coil lead wires will reach to where you are comfortable using the 
coils for extended periods of time.

 

Use the front panel carry handle  
to transport the ELEMENT Elite chassis.

Summary of Contents for ELEMENT Elite

Page 1: ...1 1 Dual Coil PEMF System Owner s Manual 3 Dec 2017 V1 ELEMENT Elite...

Page 2: ...op smart phone or tablet and sent as an audio signal to the ELEMENT Elite chassis The powerful amplifier in the ELEMENT Elite chassis amplifies the audio signal and sends it out to the ELEMENT Elite c...

Page 3: ...to that page in the manual Contents Unpacking 4 Placement 4 A Guided Tour Of the Element Elite PEMF System 5 Understanding the Element Elite Chassis 5 Protection Mode LED Lights 5 Signal Type Led 6 S...

Page 4: ...e comfortable using the coil for extended periods of time Make sure the back of the chassis is not closer than 1 from a wall to avoid blocking the cooling fans air flow 4 UNPACKING your ELEMENT Elite...

Page 5: ...WN If you do the system fans will turn off and it will take much longer to cool AGUIDEDTOURoftheELEMENTElitePEMFsystem UNDERSTANDING THE ELEMENT Elite CHASSIS As with any sophisticated piece of equipm...

Page 6: ...valuable common sense feature It actually directly senses current from the wire leading to the coil and reports to the LED If this LED is not lit when you re sure a signal is going to the ELEMENT Eli...

Page 7: ...ht up There is no problem operating the unit standing up if you want to When placed on a table the ELEMENT Elite telescoping handle adds only about to the overall height of the unit and hides complete...

Page 8: ...rce device such as a smart phone MP3 player tablet or laptop We strongly recommend using a laptop Plug the other end of the audio cable into the ELEMENT Elite chassis audio input socket The other fron...

Page 9: ...ord audio cable from the laptop and both coils as explained in the previous steps Push the coil plug into the jack and turn clockwise until it latches you should hear a click 2 Open your signal genera...

Page 10: ...gh experimentation it provides improved benefit How much higher the volume will need to be depends on the issue you are working on For pathogens you will need to increase the volume to find the MOR Mo...

Page 11: ...vier than it needs to be 3 Forces you to use it on the floor 4 Adds considerable cost and 5 Compromises your home decor Our solution is to make the chassis itself mobile We do this by replacing the fe...

Page 12: ...Initiated Field Effects is both a term coined by Dr James Bare D C who pioneers research in biology and warm fusion plasma instruments using frequency therapy and the pioneering work of The Rife machi...

Page 13: ...nce and to make and save files of those multiple frequencies You can try it for free but it will ask you to buy it after using it a few times Discounts are often offered on their site Here is the site...

Page 14: ...t REVIEW the following before operating your ELEMENT Elite The ELEMENT Elite PEMF System is a precision laboratory grade instrument for applying the beneficial properties of PEMF to your body It is re...

Page 15: ...ions 1 applying frequencies to kill pathogens in the body that originated from outside the body and are causing the body harm 2 applying frequencies that give the body signals at the cellular level to...

Page 16: ...that matches the resonant frequency of the glass will combine to be louder because they add to each other Everything has a natural resonance frequency From the smallest things like an atom or molecule...

Page 17: ...ignal things to happen but our bodies are actually an electromagnetic system since all electrical systems are electromagnetic This is why the body responds very well to PEMF Fortunately for us the ran...

Page 18: ...ral there are cases where putting the coil in particular places on your body is somewhat important Likewise for both types there are cases where it is not so important and a good rule of thumb is to p...

Page 19: ...abetes the coil should be placed down by your feet Once again comfort is important The coil does not have to be on you or in contact with you Placing the coil beside you is quite acceptable so long as...

Page 20: ...get rid of You have two choices to remedy this The first is to increase the rate of expulsion with a proper detoxification protocol and the second is to reduce the rate of kill off by using a shorter...

Page 21: ...ke needing an antibiotic you want one that acts quickly but you would never think of taking the entire prescription at once thinking it would work faster it would instead cause more problems than what...

Page 22: ...sh even if only slightly the effectiveness of the session When setting up for a session choose a place where you can be comfortable If the weight of the coil is too much use a towel to pad it When pos...

Page 23: ...Type LED may come on RED for less than a second when you first start your Frequency Generator software 6 Enjoy the benefits of the ELEMENT Elite Ending a Session When your session for the day is finis...

Page 24: ...lume actually used with the software If you change devices or have more than one you routinely use see the section on INITIAL SET UP When it comes to volume start out low Imagine you bring home a bran...

Page 25: ...a program the light may go out during that time but you will still be getting a magnetic field in the coil Chassis makes loud humming sound when turned on This is caused by dirty AC power Try a differ...

Page 26: ...cycle time Square wave recommended but any wave form the signal generator program supports can be used Tested to 10 000hz The best usable range is 7 2 800hz Structural design low voltage system and m...

Reviews: