VS-32-L
46
Fig. 21: Swinging out sealing unit.
Fig. 22: Remove linking bolts.
33
116
48 47
9.9. Dismounting and mounting the clamp
To dismount the clamps relieve tension springs
(116)
by means of spring hooks.
Swing out sealing unit. Unscrew cover
(33)
and swing out clamp holder
(45)
incl.
clamp
(47) (fig. 21)
. Remove bolts
(48)
and clamp holder incl. clamp from the
sealing unit.
After the check or the replacement slip the clamp including holder onto the rocker
(37)
and link it to the bolt. Fasten cover and close sealing unit. Slightly lubricate all
sliding surfaces. Finally suspend the tension springs.
B 13 GB 26/06