5. Technical Specification
Linearity
±1.0% of reading over flow range
Repeatability
±0.1% from 25% to 100%
±0.5% from 0% to 25%
Housing
IP54
Temperature range
-10 to 60°C assembly with enclosed electronics
-10 to 110°C sensor only (for use with remote
electronics)
-10 to 60°C remote electronics
Fluid temperature range
-10 to 60°C or -10 to 110°C with remote electronics
Storage temperature
-20 to 110
°C
Pressure rating
10 bar standard, 30 bar with stainless steel end fittings
Pulse output
PNP or NPN maximum frequency 1000Hz
Relay
24V dc 500mA max non inductive
PIN 6 transistor output
PNP 24V @ 20mA maximum
Input
Pull down resistor required (10kΩ)
PIN 7 transistor output
NPN 24V @20mA maximum
Input
Pull up resistor required (10kΩ)
LCD display
Reflective
6x8mm high main characters
2.5mm enunciators
Gal. ml. kg. gm. L. /sec. /min. /Hr
4
–
20mA output
Into 250Ω maximum
14 bit resolution
±0.1% linearity (plus flowmeter accuracy)
0
–
10 Volt output
14 bit resolution (14V dc min power supply)
±0.1% linearity (plus flowmeter accuracy)
0
–
5 Volt output
12 bit resolution
USB
TypeA connector Windows XP or later
Wiring terminals
2.5mm maximum
Power supply
9
–
24V dc (15
–
24V dc for 4-20mA or 0-10V output)
Power consumption
110mA (plus analog current)
Connections
½” BSP male PEEK or ½” NPT or BSP 316. 3/8” John
Guest push-in