Rate DP Position:
Use the drop-down menu to choose the
default decimal point position.
Total DP Position:
Use the drop-down menu to choose the
default decimal point position.
If the decimal point is set too low and the display value
exceeds the setting capacity the display will auto-range.
Viewing Filter:
This prevents the display, flow switches and
analog outputs from jittering with irregularities in the flow by
averaging the results over a short amount of time. The
increments are arbitrary with the degree of damping
approximately doubling with each level. At level 5 the
display may take up to a minute to accurately reflect any
changes in the flow.
NOTE:
This filter affects the Flow LCD display and the
analog outputs only.
Flow Switch alarms operate using the Filtered Flow
It has no effect on the NPN and PNP outputs which report
the unfiltered flow reading.