background image

 

11

 

 

1.4.2.2 The turnstile’s status (

Fig

. 5

) is displayed by the LEDs 

1,2,

 installed on the pedestal 

frame  elements.  Constantly  lit  blue  LED  means  the  turnstile  initial  state.  In  case  of  attempt  of 
unauthorized  access  red  LED  starts  blinking  and  sound  signal  is  generated.  When  opening 
command is received, signal is transformed to green arrow from the side of authorized access. If 
unauthorized  access  is  attempted  when  blades  are  open,  the  blades  will  close  if  there  is  no  any 
obstacle in the blade movement area

1.4.2.3 

Seven  infrared  sensors 

3

,  located  on  the  turnstile  side  panels  from  access  side,  are 

designed  for  detection  of  the  turnstile  access,  preventing  closing  of  blades  during  pedestrian 
access  in  immediate  proximity  to  them  and  minimizing  potential  for  injury  during  the  turnstile 
access. 

1.4.2.4 Blade 

4

 is made from 10 mm thick tempered glass and is located in the middle of the 

pedestal body, pivotally connected with actuator. Each blade is actuated by separate servomotor. 
Additional  pedestal  is  equipped  with  two  servomotors  (one  per  each  access  way),  while  margin 
pedestals (left-hand and right-hand) are equipped with one servomotor. 

1.4.2.5 In case of 230V main power failure the turnstile blades will remain in the position in 

which they were, and the turnstile operation will be maintained from battery (if available). 

1.4.2.6  The  pedestal  crank-and-rocker  mechanism,  shown  in  Figure  5,  provides  reciprocal 

movement of the pedestal telescopic glass blade. 

1.4.2.7  Inside  the  turnstile  body  the  panels  are  fixed  on  which  controllers,  power  supply 

unit, battery and terminal blocks to be connected to 230V mains and control devices are located. 

Controllers РСВ.201.01.00.00 control the turnstile motors analyzing signals from magnetic 

sensor,  and  provide  motor  overload  protection.  Controllers  analyze  infrared  sensors,  receive 
control commands from peripherals (control panel, ACS etc.), control LED displays and generate 
feedback signals for ACS.  

1.4.2.8 External control panel has the following functions: single entry and single exit, entry 

and exit LOCK, free entry and exit 

1.4.3 Principle of operation 

1.4.3.1 Access cycle: 

 

1. 

In the initial  state the turnstile glass blades are located perpendicular to the body block 

access.

 

2.  The  turnstile  is  opened  for  access  in  the  direction  "А"  or  "В"  after  the  appropriate 

command from ACS or control panel is issued. 

3.  Green  arrow  is  lit  on  LED  display  and  glass  blades  go  fully  to  slots,  i.e.  they  open.  A 

pedestrian is able to access through the turnstile freely. 

4.After  pedestrian  exit  from  control  area,  the  "closed"  mode  is  set  until  next  access.  Blue 

LED is lit. Blades are reliably closed preventing attempts of unauthorized access. 

More  detailed  description  of  the  turnstile  operation  modes  is  given  in  section  1.6 

"Description and operation of controller as an integral component of the turnstile". 

 
1.4.3.2 

12V DC power voltage is provided by power supply unit.

 

1.4.3.3 

In  case  of  mains  power  supply  failure,  the  turnstile  is  automatically  switched  to 

power supply from 12V, 7A•h battery (optional), which ensures the turnstile's operation within 2 
hours.

 

1.4.3.4 

The turnstile wiring and connection diagrams are shown in Annex C.

 

Summary of Contents for SpeedBlade T3.KCD.XV.X Series

Page 1: ...TiSO PRODUCTION LTD WAIST HIGH TURNSTILE SpeedBlade 3 D V X OPERATION MANUAL AUIA177 OM 2018...

Page 2: ...malfunctions 29 4 2 Possible malfunctions 29 4 3 SpeedBlade turnstile blade initialization procedure 30 4 3 Postrepair checkout 32 5 TRANSPORTATION AND STORAGE 32 5 1 Turnstile storage 32 5 2 Turnsti...

Page 3: ...stile includes two pedestals left hand and right hand each of which has one telescopic glass blade The turnstile row is provided by installation one more or a number of additional pedestals equipped w...

Page 4: ...hould be connected to AC network with parameters specified in p 1 2 Specifications inspection adjustment and repair should be performed only after the turnstile is deenergized After the turnstile is p...

Page 5: ...imensions mm Maximum weight kg L Single Double 3 D PV 1 1000 1000 1480 233 3 D SV 1 3 D KV 1 3 D PV 2 2270 339 3 D SV 2 3 D KV 2 When the turnstile with more than two access ways is ordered B 900 290...

Page 6: ...ition Vertical deviation from vertical position no more than 1 to any side is tolerated 1 1 5 Reliability indices mean time to repair without delivery time of spare parts tools and accessories at most...

Page 7: ...or more additional pedestal with two blades reference designation 3 D V Arrangement of access ways through the turnstile 3 D V 2 is shown in Figure 2 one access way 3 D V 1 b two access ways 3 D V 2 F...

Page 8: ...t hand and right hand and one additional pedestal with two retractable glass blades The body of additional pedestal includes frame base set of side panels and doors top lid two actuators with glass bl...

Page 9: ...ushed stainless steel or polished stainless steel 1 3 6 Turnstile scope of delivery The turnstile is delivered in set a kit of pedestals depending on the number of access ways The turnstile is deliver...

Page 10: ...of stainless steel side panels 8 9 and door 10 See Fig 4 bottoms of which are rigidly fixed to the base 5 and on the top they are fixed to the frame upper plate 11 Frame is a set of brackets and posts...

Page 11: ...the turnstile body the panels are fixed on which controllers power supply unit battery and terminal blocks to be connected to 230V mains and control devices are located Controllers 201 01 00 00 contr...

Page 12: ...NGLE ACCESS IN THE DIRECTION SINGLE ACCESS IN THE DIRECTION B SINGLE ACCESS IN BOTH DIRECTIONS FREE ACCESS IN THE DIRECTION FREE ACCESS IN THE DIRECTION B FREE ACCESS IN BOTH DIRECTIONS LOCK OF ACCESS...

Page 13: ...is traced and the signal DETECTION OF ACCESS of 0 3 second duration is generated to the relevant output OUT3 or OUT4 In this state the turnstile will be until arrival of command CANCELLATION OF FREE...

Page 14: ...no obstacles in the closing area The turnstile will return to the mode preceding the ALARM mode as soon as causes of this mode disappear In this case the output OUT5 will go to passive state siren al...

Page 15: ...rface RS 485 5 4 GND COMMON WIRE 1 1 BUZ Output for connection of audible alarm The output is active in case of unauthorized access 1 type of output open collector 2 peak voltage on privacy key 60V 3...

Page 16: ...t sensor Control commands come to inputs IN1 and IN2 from the controller AUIA 206 21 20 00 Table 6 Connector contact Descriptio n Direction Designation Signal description and parameters X1 1 IN1 ENTRY...

Page 17: ...e 1 type of output open collector 2 peak voltage on privacy key 50V 3 peak current of public key 5A X2 6 MG1 EXIT Not applicable X2 7 MG2 EXIT Not applicable X2 8 MG2 EXIT Not applicable X2 9 MOT1 EXI...

Page 18: ...n time of the turnstile access in single access mode equals to 2 sec Escape door portal or pedestrian gate can be installed near the turnstile to increase the turnstile traffic flow capacity in case o...

Page 19: ...to be used Fig 8 puncher concrete drills according to diameter of anchors included in the turnstile scope of delivery extension cord kit of end and pin wrenches kit of hexagons kit of screwdrivers ha...

Page 20: ...r defects and damages as well as completeness to be checked according to the turnstile data sheet WARNING When the turnstile damages are detected or in case of shortage of delivery installation work t...

Page 21: ...is ready as follows The site surface to be flat and horizontal Thickness of concrete blinding coat under the site to be at least 150 mm WARNING The turnstile is fixed by means of Redibolt with jacket...

Page 22: ...rking due to diameter of anchors 12 120 10 for the turnstile fixation 7 Anchor jackets to be inserted into the prepared holes WARNING The turnstile installation and fixation to be performed only after...

Page 23: ...23 Fig 12 Cable entries between the turnstile Master SpeedBlade 1 pedestal Slave SpeedBlade 1 pedestal Master Slave SpeedBlade 2 double blade pedestal...

Page 24: ...available access holes in the turnstile post bottom end part by reclining the turnstile 13 Fixation holes at the turnstile bottom plate to be aligned with prepared surface holes 14 The turnstile to be...

Page 25: ...The turnstile door and side pieces Fig 17 to be installed at their fixation locations and table board to be fixed with screws Fig 17 Body installation on the turnstile frame 16 Installation of proximi...

Page 26: ...1 When the turnstile is commissioned it is necessary to perform inspections specified in Table 7 During inspections the wiring diagram according to Annex C and the control panel according to Appendix...

Page 27: ...cess in opposite direction FREE button to be pushed for access in chosen direction A or B and LOCK button to be pushed for locking access in opposite direction Green arrow of authorized free access in...

Page 28: ...vant safety measures according to p 2 1 to be observed IT IS FORBIDDEN TO USE DEFECTIVE APPLIANCES TOOLS FUSES INSTRUMENTATION THE SERVICE LIFE OF WHICH HAS EXPIRED 3 2 2 When instrumentations are pre...

Page 29: ...anual control in the modes specified in Table 7 or when identification cards are used verification of reliability of the turnstile screw joints and earthing connections 4 ROUTINE MAINTENANCE 4 1 Possi...

Page 30: ...to be checked Blade remains open Magnetic sensor is out of order Mechanism jamming FREE ACCESS mode is set Infrared sensors are out of order Blade opening to be checked manually turning off power sup...

Page 31: ...s MOT1 10 The turnstile to be energized 11 Turnstile operation to be checked 12 New zero position setting is completed Magnetic sensor and magnet gap control Normal gap is 1mm If LED is lit then gap i...

Page 32: ...install turnstile to be transported according to the transportation regulations related to the relevant mode of transport such as in railway or special containers in closed vehicles waterborne in shi...

Page 33: ...OM preventing further use of the turnstile 7 4 The Manufacturer does not bear responsibility and warranty liabilities for the turnstile damage due to nonobservance of the requirements specified by thi...

Page 34: ...European Standards EN 60335 1 2002 EN 61000 6 1 2007 EN 61000 6 3 2007 EN 61000 4 2 2009 EN 61000 4 3 2006 EN 61000 4 4 2004 EN 61000 4 5 2006 EN 61000 4 11 2004 and is in conformity with requirement...

Page 35: ...Annex mandatory Overall and installation dimensions of the SpeedBlade type turnstile T3 KCD XV 1 Fig 1 Single turnstile right hand and left hand pedestal Master and Slave...

Page 36: ...ntinued Annex Overall and installation dimensions of the SpeedBlade type turnstile T3 KCD XV 2 Fig 2 Double turnstile right hand right hand left hand and left hand pedestal Master Master Slave and Sla...

Page 37: ...ontrol panel body 5 FREE ACCESS mode control button 2 SINGLE ACCESS mode control button 6 PANIC mode control button 3 front plate 7 access direction LED display 4 LOCK mode control button 8 controller...

Page 38: ...38 Continued Annex B Control panel and connection diagram Fig B 2 Connection diagram of control panel AUIA 114 02 00 00...

Page 39: ...6 3 XP2 10 8 7 5 4 2 1 GND POW XT5 IN 5 IN 2 OUT5 OUT4 OUT2 OUT1 XT3 GND 12V 12V 2 2 1 2 4 3 XP4 1 8 7 4 5 2 1 9 6 3 XP1 IN 6 IN 3 GND IN 4 XT4 IN 1 OUT3 GND XT2 RED 2 12V 12V AUX2 AUX1 IR OUT8 IR OUT...

Page 40: ...command is issued the input is activated for 5 sec inp2 TO BE OPENED B in pulse mode When command is issued the input is activated for 5 seconds 3 PANIC inp GND of power supply common wire out3 DETEC...

Page 41: ...n pulse mode When command is issued the input is activated for 5 sec inp2 TO BE OPENED B in pulse mode When command is issued the input is activated for 5 seconds inp3 PANIC GND of power supply common...

Page 42: ...se mode When command is issued the input is activated for 5 sec inp2 TO BE OPENED B in pulse mode When command is issued the input is activated for 5 seconds inp3 PANIC GND of power supply common wire...

Page 43: ...43 Annex D 4 mandatory Diagram of the turnstile connection to control panel 5 4 3 2 1 P B A G...

Reviews: