27
Continued Table 7
1
2
3
4. Free access in
one direction
"FREE" button to be pushed for
access in chosen direction(“A” or
“B”)
Green arrow of authorized free
access in chosen direction is lit
and blue LED display in opposite
direction is lit
5. Free access in
both directions
Both "FREE" buttons to be
pushed
for
access
in
both
directions (“A” and “B”)
Green arrows of authorized free
access in both directions are lit
6. Single access in
one direction and
free access in
opposite direction
"SINGLE" button to be pushed
for access in chosen direction
(“A” or “B”) and "FREE" button
to be pushed for access in
opposite direction
Green arrow of authorized single
access in chosen direction is lit and
green arrow of authorized free
access in opposite direction is lit
7. Single access in
one direction and
locked access in
opposite direction
"SINGLE" button to be pushed
for access in chosen direction
(“A” or “B”) and "LOCK" button
to be pushed for locking access in
opposite direction
Green arrow of authorized single
access in chosen direction is lit and
red LED display of locked access is
lit
8. Free access in
one direction and
locked access in
opposite direction
"FREE" button to be pushed for
access in chosen direction (“A” or
“B”) and "LOCK" button to be
pushed for locking access in
opposite direction
Green arrow of authorized free
access in chosen direction is lit and
red LED display of locked access in
opposite direction is lit
9. Locked access in
one direction
"LOCK" button to be pushed for
locking access in chosen direction
(“A” or “B”)*
Red LED of locked access in one
chosen direction is lit
10. Locked access
in both directions
Both "LOCK" buttons to be
pushed for locking access in both
directions (“A” and “B”)**
Red LED of locked access in both
directions is lit
11. Activation of
“Panic” mode
“PANIC” button to be pushed and
hold for at least 5 s***
Green arrows of authorized free
access in both direction is lit
* In this case other control panel buttons of single and free access in selected direction are
locked;
**In this case all control panel buttons of single and free access in both directions are locked
2.3.2.2 Upon completion of the turnstile satisfactory inspection it is ready for long-term
operation.
2.4 Contingency actions
For emergency human escape (in case of fire, acts of God etc.) and ensuring free access the
turnstile to be unlocked from control panel by issuing the relevant command. For full opening of
access way an “PANIC” function to be used.