30
Continued Table 8
1
2
3
Turnstile does not obtain
actuation signal from ACS.
to be checked. Availability of
actuation signal from ACS to be
checked.
Blade knocks
Magnetic sensor to be
checked.
Magnetic sensor to be adjusted or
PCB to be replaced.
Control panel sends
sound signal
"communication"
Control panel is out of
contact with controller
Wires to be checked.
Control panel to be checked.
Controller to be checked.
LED display is out of
order
No contact with controller.
Wires are damaged.
LED display is out of order
Wires to be checked.
LED display to be checked.
LED to be replaced.
Continuous sound
signal when turnstile
is open
Infrared sensors don’t see
each other.
Infrared sensors are out of
order.
Plexiglas to be cleaned from dust.
Infrared sensors to be checked.
Infrared sensors to be replaced if they
are out of order.
Blade stays in
semiopen position
Magnetic sensor is out of
order.
Mechanism jamming.
Blade opening to be checked
manually turning off power supply.
Mechanism components to be
checked.
Sensor adjustment to be checked.
Blade remains open
Magnetic sensor is out of
order.
Mechanism jamming
“FREE ACCESS” mode is
set.
Infrared sensors are out of
order
Blade opening to be checked
manually turning off power supply.
Mechanism components to be
checked.
Sensor adjustment to be checked
Blade slow opening
Mechanism jamming.
Infrared sensors don’t see
each other.
Infrared sensors are out of
order.
Magnetic sensor to be
checked.
Check manually whether it operates
or not. Mechanism components to be
checked. Magnetic sensor to be
adjusted or PCB to be replaced
Magnetic sensor to be adjusted or
PCB to be replaced.
Wires to be checked.
4.3. “SpeedBlade” turnstile blade initialization procedure
Initial setting of the blade zero position at the first activation of the turnstile
1)
Turnstile to be deenergized;
2)
Motor to be disconnected from PCB 201terminal: MOT1 (Fig.7);
3)
Blade to be set in the required zero position ((Fig.19 and (Fig.20);
4)
The turnstile to be energized;
5)
Zero position setting button on magnetic sensor board to be pushed and hold for at
least 1 second, then to be released (make sure that the button pressure force does not
bend the board);
6)
After the button on the magnetic sensor board is released the zero position LED to be
lit;