25
Fig.16
–
Connection of control panel
communication cable to terminals PCB
206.21.00.00
-
G
(GND)
–
common wire of control
panel;
-
A
(RSA)
–
RSA wire of control panel
link;
-
B
(RSB)
–
RSB wire of control panel
link;
c)
The turnstile to be earthed, power supply
cable to be connected the turnstile
according to wiring diagrams (See
Annex B).
d)
Proximity card readers to be installed, if
access control system (ACS) is available.
The turnstile door and side pieces (
Fig.17
)
to be installed at their fixation locations and table
board to be fixed with screws.
Fig. 17
–
Body installation on the turnstile frame
16) Installation of proximity card reader
upon the availability of access control system
(ACS)
-
The turnstile table board to be removed;
-
Screws to be unscrewed and acrylic to be removed;
-
Maximum size of the card reader to be installed is not more than
80x80x25 mm
(
See Fig.18
);
-
Acrylic to be secured with screws in previous position;
-
The turnstile table board to be installed and secured with screws in previous position.
Door
Frame base