UM-6
Fig. 21
4) Before re-assembling the new sliding block be sure that
the original lubricating nipples are not assembled.
Take care about the orientation of the sliding block.
The side of the lubrication tank must be on the outer
side.
For re-assembly, reverse the operations described above.
During insertion, the new sliding block will be inserted auto-
matically in the fast disconnect of the grease block.
5) Fix the sliding block with its 4 screws.
6) Re-assembly the cover plate.
Replacement of the ball re-circulation sliding blocks
Fig. 19
1) Remove the cover plate on top or lower side of the
carriage depending where the sliding block has to
be replaced. Unscrew the two screws (see Fig.19).
2) Loosen and remove the sliding block screws.
3) Slide out the sliding block. In case the seal OR is removed
during this operation, it must be re-positioned when
re-assembling the sliding block (see Fig. 21).
Fig. 20
SC
Summary of Contents for ROLLON SC 100
Page 1: ...Smart System Use and maintenance Actuator Line Plus system SC ...
Page 2: ......
Page 17: ...UM 15 Smart System ...