UM-2
SC
Lubrication
Quantity of lubricant for each block
Insert the tip of the grease gun in the specific grease blocks.
For lubrication of linear units use lithium soap grease NLGI 2.
For specially stressed applications or difficult enviromental condi-
Type
Unit
[cm
3
]
SC 100
0.7
SC 130
0.7
SC 160
1.4
Use and maintenance
Tab. 1
Fig. 1
Linear units with linear ball guides
SC Linear units are equipped with self lubricating linear ball
guides. On the front plates of the linear blocks special lu-
be-units are mounted which are continuously providing the
necessary quantity of grease to the ball rows under load.
tions, lubrication should be carried out more frequently. Apply to
Rollon for futher advice.
This system guarantees a long interval between maintenan-
ces: every 5000 km or 1 year of use, based on the value
reached first. If a longer service life is required or in case of
high dynamic or high loaded applications please contact our
offices for further verification.
Fig. 2
Fig. 3
Drive belt replacement
1) Untight the 4 screws which fix the upper belt clamp (Fig. 2).
2) Remove the cap which covers the tensioning screw, untight
the set-screw. Remove the tensioning screw (see Fig. 3).