19
8.2.3. Weekly programming
NOTE:
Make sure that the starting up and shutting down time does not overlap.It is also necessary
to pay attention that between this two processes pass at least 30 minutes.
During the daily programming you can set four starting ups and four shutting downs of the system.
Also you may set the activation of the specific program for a specific day.
Press the key 3 (set) and you will get a displayed message
menu 01 SET CLOCK
. Afterward you
need to press the key 5 twice, and on display will be written
menu 02 SET CHRONO
. Pressing the
key 3 (set) you access the timer setting menu, and consequently in the menu for turning the timer
on. On display will show up
m-2-1 ENABLE CHRONO
. Then again press the key 5 twice and the
display will show
m-2-3 PROGRAM WEEK.
MENU
SETING
OPTIONS
DISPLAY APPEARANCE
m-2-2-01 CHRONO DAY
off/on
m-2-2-02 START 1 DAY
off/00:00-23:50
m-2-2-03 STOP 1 DAY
off/00:00-23:50
m-2-2-04 START 2 DAY
off/00:00-23:50
m-2-2-05 STOP 2 DAY
off/00:00-23:50