27
SPEAKER ON
SPEAKER OFF
To exit the timer setting press the key 4 twice.
8.7. Initial pellet loading
When stof i sour of pellet, dosier is empty also se after the storage is filled again it takes some time
to fill the dosier to so the stove could start When storage is empty
Alarm 6
appears which is
described in chapter ERRORS.
After loading pellets into the storage, it is necessary to do the following:
Press the key 3 (set) and you will get a displayed message menu
01 ADJUST BLOWERS.
Afterward you need to press the key 5 six times, and on display will be written
menu 07 MODE
LOAD INITIAL
. By pressing the key 3 (set), ), you access the menu for the initial loading of
pellets, after what will appear a message
off menu 07 P1 TO LOAD
, which means you have to
press the key 1to begin charging a dozer. It takes arround 45 seconds to fill the dozer but it is best
to stop charging once the first pellets is in the pot which is visually noticable.
The appearance of the display when you start inserting pellets is shown
in the figure below. The countdown starts from 90 seconds
back and down.
To stop loading pellets press the key 4.
x 6