35
Appearance of the stove when opening the inspection covers of the boiler.
When cleaning inspection opening on the lid of the boiler, it is necessary to unscrew the 6 bolt
head first, and then remove the cover of the inspection opening. Then remove the ash
accumulated on the surface of the opening and clean the boiler tubes. This needs to be done first
because the ash will fall into the chamber beneath the boiler.
For setting the lid, apply the procedure backwards.Watch out for the seal, which is located under
the cover, in order to avoid possible damages.
Cleaning of the inspection opening is being done by removing an ashtrays and then loosening 4
screws that hold the cover. Remove the dust that has been accumulated behind the inspection
opening and
put everything on it’s place. Pay attention to the seal which is attached to the cover.
For cleaning of the fan inspect
ion opening it’s necessary to remove the side panel, by loosening
the screws on the rear side of the stove and bolts that are located on the side of the stove.
Summary of Contents for rittium 14 hydro
Page 2: ...2...
Page 37: ...37 Distributor authorized service...
Page 38: ...38 13 ANNEX A CONECTING TO A HEATING INSTALATION CHEME...
Page 39: ...39 14 ANNEX B CONNECTING TO CONTROL UNIT CHEME...
Page 43: ...43...